TY - JOUR
T1 - A colorimetric paper-based analytical device coupled with hollow fiber membrane liquid phase microextraction (HF-LPME) for highly sensitive detection of hexavalent chromium in water samples
AU - Alahmad, Waleed
AU - Tungkijanansin, Nuttanee
AU - Kaneta, Takashi
AU - Varanusupakul, Pakorn
N1 - Funding Information:
This research is supported by Rachadapisek Sompot Fund for Postdoctoral Fellowship, Chulalongkorn University. T. K. acknowledges to the support by JSPS KAKENHI Grant number 17H05465 .
Publisher Copyright:
© 2018 Elsevier B.V.
PY - 2018/12/1
Y1 - 2018/12/1
N2 - A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.
AB - A simple and highly sensitive procedure based on the combination of hollow fiber membrane liquid phase microextraction and a microfluidic paper-based analytical device (µPAD) was developed for pre-concentration and determination of hexavalent chromium in water samples. The hexavalent chromium was pre-concentrated using the HF-LPME technique via ion exchange or a coupled transport process through a supported ionic liquid (Aliquat 336) prior to colorimetric detection with diphenylcarbazide on the µPAD. The violet colour could be seen by the naked eye. Images from the µPADs were scanned using a commercial desktop scanner at 600 dpi resolution. ImageJ software was used for quantitative analysis by measuring the intensity values at green colour channel since it gave the best sensitivity among the RGB colour. Under optimal conditions, the calibration curve was linear in the range 10–90 µg L-1, with a limit of detection of 3 µg L-1. The developed method was successfully applied to determine the level of hexavalent chromium spiked into natural water samples at the parts-per-billion (ppb) level, and the results were in good agreement with those obtained using inductively coupled plasma atomic emission spectroscopy (ICP-AES). The developed method was able to improve the detection limit of the conventional µPAD, and was expected to be used for the effective analysis of hexavalent chromium in natural water.
KW - Colorimetric detection
KW - Hexavalent chromium
KW - Hollow fiber membrane liquid phase microextraction
KW - Microfluidic paper-based analytical devices
UR - http://www.scopus.com/inward/record.url?scp=85050468889&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85050468889&partnerID=8YFLogxK
U2 - 10.1016/j.talanta.2018.07.056
DO - 10.1016/j.talanta.2018.07.056
M3 - Article
C2 - 30172544
AN - SCOPUS:85050468889
SN - 0039-9140
VL - 190
SP - 78
EP - 84
JO - Talanta
JF - Talanta
ER -