TY - JOUR
T1 - Accurate determination of 234U/238U and 230Th/232Th for U-Th disequilibria studies by MC-ICP-MS with simple bracketing
AU - Makishima, Akio
AU - Chekol, Takele A.
AU - Nakamura, Eizo
PY - 2007/10/29
Y1 - 2007/10/29
N2 - Accurate determination methods for 234U/238U and 230Th/232Th using multiple collector (MC) ICP-MS with a single secondary electron multiplier through a retarding potential quadrupole filter (RPQ-SEM) have been developed. The RPQ-SEM yield and the instrumental mass discrimination were simultaneously corrected by the simple bracketing method which utilizes accurately determined standard solutions measured by TIMS. For the bracketing and as an evaluation of the precision of the method, four standard solutions, NBL-145 U and U-m for U, and Th-I and Th-II for Th, were prepared, and NBL-145 U and Th-I were used as bracketing standards. The U and Th amounts of 0.5-21 ng and 0.6-21 ng used in U-m and Th-II analyses gave intermediate precisions (2RSD) of 0.85-0.06 and 0.88-0.19%, respectively, and vary from TIMS measurements by <0.35 and <1.1%, respectively, which agrees with error values in TIMS analyses. To achieve similar intermediate precisions of 0.2 and 0.6% (2RSD) in the U and Th isotope analyses to that of TIMS, 3 and 2 ng of U and Th are sufficient. When only the isotope analysis is performed, the required amounts of U and Th can be reduced by half. The precision of the isotope analyses, as well as the concentration determinations, were further confirmed by analyses of U and Th separated from the GSJ standard basalt, JB-2.
AB - Accurate determination methods for 234U/238U and 230Th/232Th using multiple collector (MC) ICP-MS with a single secondary electron multiplier through a retarding potential quadrupole filter (RPQ-SEM) have been developed. The RPQ-SEM yield and the instrumental mass discrimination were simultaneously corrected by the simple bracketing method which utilizes accurately determined standard solutions measured by TIMS. For the bracketing and as an evaluation of the precision of the method, four standard solutions, NBL-145 U and U-m for U, and Th-I and Th-II for Th, were prepared, and NBL-145 U and Th-I were used as bracketing standards. The U and Th amounts of 0.5-21 ng and 0.6-21 ng used in U-m and Th-II analyses gave intermediate precisions (2RSD) of 0.85-0.06 and 0.88-0.19%, respectively, and vary from TIMS measurements by <0.35 and <1.1%, respectively, which agrees with error values in TIMS analyses. To achieve similar intermediate precisions of 0.2 and 0.6% (2RSD) in the U and Th isotope analyses to that of TIMS, 3 and 2 ng of U and Th are sufficient. When only the isotope analysis is performed, the required amounts of U and Th can be reduced by half. The precision of the isotope analyses, as well as the concentration determinations, were further confirmed by analyses of U and Th separated from the GSJ standard basalt, JB-2.
UR - http://www.scopus.com/inward/record.url?scp=35448938764&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=35448938764&partnerID=8YFLogxK
U2 - 10.1039/b706907c
DO - 10.1039/b706907c
M3 - Article
AN - SCOPUS:35448938764
SN - 0267-9477
VL - 22
SP - 1383
EP - 1389
JO - Journal of analytical atomic spectrometry
JF - Journal of analytical atomic spectrometry
IS - 11
ER -