T1 - Additional diagnostic value of first-pass myocardial perfusion imaging without stress when combined with 64-row detector coronary CT angiography in patients with coronary artery disease
AU - Osawa, Kazuhiro
AU - Miyoshi, Toru
AU - Koyama, Yasushi
AU - Hashimoto, Katsushi
AU - Sato, Shuhei
AU - Nakamura, Kazufumi
AU - Nishii, Nobuhiro
AU - Kohno, Kunihisa
AU - Morita, Hiroshi
AU - Kanazawa, Susumu
AU - Ito, Hiroshi
PY - 2014/7
Y1 - 2014/7
N2 - Objective: Multi-detector coronary CT angiography (CCTA) can detect coronary stenosis, but it has a limited ability to evaluate myocardial perfusion. We evaluated the usefulness of first-pass CT-myocardial perfusion imaging (MPI) in combination with CCTA for diagnosing coronary artery disease (CAD). Methods: A total of 145 patients with suspected CAD were enrolled. We used 64-row multi-detector CT (Definition Flash, Siemens). The same coronary CCTA data were used for first-pass CT-MPI without drug loading. Images were reconstructed by examining the signal densities at diastole as colour maps. Diagnostic accuracy was assessed by comparison with invasive coronary angiography. Results: First-pass CT-MPI in combination with CCTA significantly improved diagnostic performance compared with CCTA alone. With per-vessel analysis, the sensitivity, specificity, positive predictive value and negative predictive value increased from 81% to 85%, 87% to 94%, 63% to 79% and 95% to 96%, respectively. The area under the receiver operating characteristic curve for detecting CAD also increased from 0.84 to 0.89 (p=0.02). First-pass CT-MPI was particularly useful for assessing segments that could not be directly evaluated due to severe calcification and motion artefacts. Conclusions: First-pass CT-MPI has an additional diagnostic value for detecting coronary stenosis, in particular in patients with severe calcification.
AB - Objective: Multi-detector coronary CT angiography (CCTA) can detect coronary stenosis, but it has a limited ability to evaluate myocardial perfusion. We evaluated the usefulness of first-pass CT-myocardial perfusion imaging (MPI) in combination with CCTA for diagnosing coronary artery disease (CAD). Methods: A total of 145 patients with suspected CAD were enrolled. We used 64-row multi-detector CT (Definition Flash, Siemens). The same coronary CCTA data were used for first-pass CT-MPI without drug loading. Images were reconstructed by examining the signal densities at diastole as colour maps. Diagnostic accuracy was assessed by comparison with invasive coronary angiography. Results: First-pass CT-MPI in combination with CCTA significantly improved diagnostic performance compared with CCTA alone. With per-vessel analysis, the sensitivity, specificity, positive predictive value and negative predictive value increased from 81% to 85%, 87% to 94%, 63% to 79% and 95% to 96%, respectively. The area under the receiver operating characteristic curve for detecting CAD also increased from 0.84 to 0.89 (p=0.02). First-pass CT-MPI was particularly useful for assessing segments that could not be directly evaluated due to severe calcification and motion artefacts. Conclusions: First-pass CT-MPI has an additional diagnostic value for detecting coronary stenosis, in particular in patients with severe calcification.
UR - http://www.scopus.com/inward/record.url?scp=84902386762&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84902386762&partnerID=8YFLogxK
U2 - 10.1136/heartjnl-2013-305468
DO - 10.1136/heartjnl-2013-305468
M3 - Article
C2 - 24763490
AN - SCOPUS:84902386762
SN - 1355-6037
VL - 100
SP - 1008
EP - 1015
JO - Heart
JF - Heart
IS - 13
ER -