TY - JOUR
T1 - Biomechanical loading comparison between titanium and unsintered hydroxyapatite/poly-L-lactide plate system for fixation of mandibular subcondylar fractures
AU - Sukegawa, Shintaro
AU - Kanno, Takahiro
AU - Yamamoto, Norio
AU - Nakano, Keisuke
AU - Takabatake, Kiyofumi
AU - Kawai, Hotaka
AU - Nagatsuka, Hitoshi
AU - Furuki, Yoshihiko
N1 - Funding Information:
Acknowledgments: We declare no financial support from Teijin Co., Ltd., Osaka, Japan. Some analyses, such as those of tensile and shear strength and biomechanical loading evaluations, were performed at the Teijin Medical Institute, Okayama, Japan.
Funding Information:
Funding: This work was supported by JSPS KAKENHI Grant Number 20837661.
Publisher Copyright:
© 2019 by the authors.
PY - 2019
Y1 - 2019
N2 - Osteosynthesis absorbable materials made of uncalcined and unsintered hydroxyapatite (u-HA) particles, poly-l-lactide (PLLA), and u-HA/PLLA are bioresorbable, and these plate systems have feasible bioactive osteoconductive capacities. However, their strength and stability for fixation in mandibular subcondylar fractures remain unclear. This in vitro study aimed to assess the biomechanical strength ofu-HA/PLLAbioresorbable plate systems after internal fixation of mandibular subcondylar fractures. Tensile and shear strength were measured for each u-HA/PLLA and titanium plate system. To evaluate biomechanical behavior, 20 hemimandible replicas were divided into 10 groups, each comprising a titanium plate and a bioresorbable plate. A linear load was applied anteroposteriorly and lateromedially to each group to simulate the muscular forces in mandibular condylar fractures. All samples were analyzed for each displacement load and the displacement obtained by the maximum load. Tensile and shear strength of the u-HA/PLLA plate were each approximately 45% of those of the titanium plates. Mechanical resistance was worst in the u-HA/PLLA plate initially loaded anteroposteriorly. Titanium plates showed the best mechanical resistance during lateromedial loading. Notably, both plates showed similar resistance when a lateromedially load was applied. In the biomechanical evaluation of mandibular condylar fracture treatment, the u-HA/PLLA plates had sufficiently high resistance in the two-plate fixation method.
AB - Osteosynthesis absorbable materials made of uncalcined and unsintered hydroxyapatite (u-HA) particles, poly-l-lactide (PLLA), and u-HA/PLLA are bioresorbable, and these plate systems have feasible bioactive osteoconductive capacities. However, their strength and stability for fixation in mandibular subcondylar fractures remain unclear. This in vitro study aimed to assess the biomechanical strength ofu-HA/PLLAbioresorbable plate systems after internal fixation of mandibular subcondylar fractures. Tensile and shear strength were measured for each u-HA/PLLA and titanium plate system. To evaluate biomechanical behavior, 20 hemimandible replicas were divided into 10 groups, each comprising a titanium plate and a bioresorbable plate. A linear load was applied anteroposteriorly and lateromedially to each group to simulate the muscular forces in mandibular condylar fractures. All samples were analyzed for each displacement load and the displacement obtained by the maximum load. Tensile and shear strength of the u-HA/PLLA plate were each approximately 45% of those of the titanium plates. Mechanical resistance was worst in the u-HA/PLLA plate initially loaded anteroposteriorly. Titanium plates showed the best mechanical resistance during lateromedial loading. Notably, both plates showed similar resistance when a lateromedially load was applied. In the biomechanical evaluation of mandibular condylar fracture treatment, the u-HA/PLLA plates had sufficiently high resistance in the two-plate fixation method.
KW - Bioactive resorbable plate
KW - Biomechanical loading evaluation
KW - Fracture fixation
KW - Mandibular condylar fracture
KW - Unsintered hydroxyapatite/poly-l-lactide composite plate
UR - http://www.scopus.com/inward/record.url?scp=85065726605&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85065726605&partnerID=8YFLogxK
U2 - 10.3390/ma12091557
DO - 10.3390/ma12091557
M3 - Article
AN - SCOPUS:85065726605
SN - 1996-1944
VL - 12
JO - Materials
JF - Materials
IS - 9
M1 - 1557
ER -