TY - JOUR
T1 - Determination of iron ion in the water of a natural hot spring using microfluidic paper-based analytical devices
AU - Ogawa, Kazuma
AU - Kaneta, Takashi
N1 - Funding Information:
This research was supported by The Yakumo Foundation for Environmental Science and Grants-in-Aid for Scientific Research, Scientific Research (B) (No. 26288067) from the Japan Society for the Promotion of Science.
Publisher Copyright:
© 2016 The Japan Society for Analytical Chemistry.
PY - 2016
Y1 - 2016
N2 - Microfluidic paper-based analytical devices (μPADs) were used to detect the iron ion content in the water of a natural hot spring in order to assess the applicability of this process to the environmental analysis of natural water. The μPADs were fabricated using a wax printer after the addition of hydroxylamine into the detection reservoirs to reduce Fe 3+ to Fe 2+ , 1,10-phenanthroline for the forming of a complex, and poly(acrylic acid) for ion-pair formation with an acetate buffer (pH 4.7). The calibration curve of Fe 3+ showed a linearity that ranged from 100 to 1000 ppm in the semi-log plot whereas the color intensity was proportional to the concentration of Fe 3+ and ranged from 40 to 350 ppm. The calibration curve represented the daily fluctuation in successive experiments during four days, which indicated that a calibration curve must be constructed for each day. When freshly prepared μPADs were compared with stored ones, no significant difference was found. The μPADs were applied to the determination of Fe 3+ in a sample of water from a natural hot spring. Both the accuracy and the precision of the μPAD method were evaluated by comparisons with the results obtained via conventional spectrophotometry. The results of the μPADs were in good agreement with, but less precise than, those obtained via conventional spectrophotometry. Consequently, the μPADs offer advantages that include rapid and miniaturized operation, although the precision was poorer than that of conventional spectrophotometry.
AB - Microfluidic paper-based analytical devices (μPADs) were used to detect the iron ion content in the water of a natural hot spring in order to assess the applicability of this process to the environmental analysis of natural water. The μPADs were fabricated using a wax printer after the addition of hydroxylamine into the detection reservoirs to reduce Fe 3+ to Fe 2+ , 1,10-phenanthroline for the forming of a complex, and poly(acrylic acid) for ion-pair formation with an acetate buffer (pH 4.7). The calibration curve of Fe 3+ showed a linearity that ranged from 100 to 1000 ppm in the semi-log plot whereas the color intensity was proportional to the concentration of Fe 3+ and ranged from 40 to 350 ppm. The calibration curve represented the daily fluctuation in successive experiments during four days, which indicated that a calibration curve must be constructed for each day. When freshly prepared μPADs were compared with stored ones, no significant difference was found. The μPADs were applied to the determination of Fe 3+ in a sample of water from a natural hot spring. Both the accuracy and the precision of the μPAD method were evaluated by comparisons with the results obtained via conventional spectrophotometry. The results of the μPADs were in good agreement with, but less precise than, those obtained via conventional spectrophotometry. Consequently, the μPADs offer advantages that include rapid and miniaturized operation, although the precision was poorer than that of conventional spectrophotometry.
KW - Environmental analysis
KW - Hot spring
KW - Iron ion
KW - Microfluidic paper-based analytical device
UR - http://www.scopus.com/inward/record.url?scp=84959295473&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84959295473&partnerID=8YFLogxK
U2 - 10.2116/analsci.32.31
DO - 10.2116/analsci.32.31
M3 - Article
C2 - 26753702
AN - SCOPUS:84959295473
SN - 0910-6340
VL - 32
SP - 31
EP - 34
JO - Analytical Sciences
JF - Analytical Sciences
IS - 1
ER -