TY - JOUR
T1 - Determination of molybdenum, antimony and tungsten at sub μg g -1 levels in geological materials by ID-FI-ICP-MS
AU - Makishima, Akio
AU - Nakamura, Eizo
PY - 1999/12/1
Y1 - 1999/12/1
N2 - We have developed a rapid and accurate method for the determination of Mo, Sb and W in geological samples using isotope dilution inductively coupled plasma-mass spectrometry with a flow injection system (ID-FI-ICP-MS). The chemical procedure requires HF digestion of the sample with a Mo-Sb-W mixed spike, subsequent evaporation and dissolution of Mo, Sb and W from Mg and Ca fluorides with HF. Recovery yields of Mo, Sb and W in the extraction were > 94% for samples of peridotite, basalt and andesite composition, with the exception of W in samples of peridotite composition for which recovery was 81%. No matrix effects were observed in the determination of the isotope ratios of Mo, Sb and W in solutions prepared from peridotite, basalt and andesite samples down to a dilution factor of 100. Detection limits of Mo, Sb and W in silicate materials were at the several ng g-1 level. Analysis of the silicate reference materials PCC-1, DTS-1, BCR-1, BHVO-1, AGV-1 from the US Geological Survey and JP-1, JB-1, -2, -3, JA-1, -2, and -3 from the Geological Survey of Japan as well as the Smithsonian reference Allende powder yielded reliable Mo, Sb and W concentrations. The repeatability in the analysis of basalts and andesites was < 9%. This technique requires only 0.2 ml sample solution, and is therefore suitable for analyzing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates.
AB - We have developed a rapid and accurate method for the determination of Mo, Sb and W in geological samples using isotope dilution inductively coupled plasma-mass spectrometry with a flow injection system (ID-FI-ICP-MS). The chemical procedure requires HF digestion of the sample with a Mo-Sb-W mixed spike, subsequent evaporation and dissolution of Mo, Sb and W from Mg and Ca fluorides with HF. Recovery yields of Mo, Sb and W in the extraction were > 94% for samples of peridotite, basalt and andesite composition, with the exception of W in samples of peridotite composition for which recovery was 81%. No matrix effects were observed in the determination of the isotope ratios of Mo, Sb and W in solutions prepared from peridotite, basalt and andesite samples down to a dilution factor of 100. Detection limits of Mo, Sb and W in silicate materials were at the several ng g-1 level. Analysis of the silicate reference materials PCC-1, DTS-1, BCR-1, BHVO-1, AGV-1 from the US Geological Survey and JP-1, JB-1, -2, -3, JA-1, -2, and -3 from the Geological Survey of Japan as well as the Smithsonian reference Allende powder yielded reliable Mo, Sb and W concentrations. The repeatability in the analysis of basalts and andesites was < 9%. This technique requires only 0.2 ml sample solution, and is therefore suitable for analyzing small and/or precious samples such as meteorites, mantle peridotites and their mineral separates.
KW - Flow injection
KW - ICP-MS
KW - Isotope dilution
KW - Method development
KW - Mo
KW - Reference materials
KW - Sb
KW - W
UR - http://www.scopus.com/inward/record.url?scp=0000219433&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0000219433&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.1999.tb00569.x
DO - 10.1111/j.1751-908X.1999.tb00569.x
M3 - Article
AN - SCOPUS:0000219433
SN - 0150-5505
VL - 23
SP - 137
EP - 148
JO - Geostandards Newsletter
JF - Geostandards Newsletter
IS - 2
ER -