T1 - Dose distribution of intensity-modulated proton therapy with and without a multi-leaf collimator for the treatment of maxillary sinus cancer
T2 - A comparative effectiveness study
AU - Sugiyama, Soichi
AU - Katsui, Kuniaki
AU - Tominaga, Yuki
AU - Waki, Takahiro
AU - Katayama, Norihisa
AU - Matsuzaki, Hidenobu
AU - Kariya, Shin
AU - Kuroda, Masahiro
AU - Nishizaki, Kazunori
AU - Kanazawa, Susumu
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019/11/21
Y1 - 2019/11/21
N2 - Background: Severe complications, such as eye damage and dysfunciton of salivary glands, have been reported after radiotherapy among patients with head and neck cancer. Complications such as visual impairment have also been reported after proton therapy with pencil beam scanning (PBS). In the case of PBS, collimation can sharpen the penumbra towards surrounding normal tissue in the low energy region of the proton beam. In the current study, we examined how much the dose to the normal tissue was reduced by when intensity-modulated proton therapy (IMPT) was performed using a multi-leaf collimator (MLC) for patients with maxillary sinus cancer. Methods: Computed tomography findings of 26 consecutive patients who received photon therapy at Okayama University Hospital were used in this study. We compared D2% of the region of interest (ROI; ROI-D2%) and the mean dose of ROI (ROI-mean) with and without the use of an MLC. The organs at risk (OARs) were the posterior retina, lacrimal gland, eyeball, and parotid gland. IMPT was performed for all patients. The spot size was approximately 5-6 mm at the isocenter. The collimator margin was calculated by enlarging the maximum outline of the target from the beam's eye view and setting the margin to 6 mm. All plans were optimized with the same parameters. Results: The mean of ROI-D2% for the ipsilateral optic nerve was significantly reduced by 0.48 Gy, and the mean of ROI-mean for the ipsilateral optic nerve was significantly reduced by 1.04 Gy. The mean of ROI-mean to the optic chiasm was significantly reduced by 0.70 Gy. The dose to most OARs and the planning at risk volumes were also reduced. Conclusions: Compared with the plan involving IMPT without an MLC, in the dose plan involving IMPT using an MLC for maxillary sinus cancer, the dose to the optic nerve and optic chiasm were significantly reduced, as measured by the ROI-D2% and the ROI-mean. These findings demonstrate that the use of an MLC during IMPT for maxillary sinus cancer may be useful for preserving vision and preventing complications.
AB - Background: Severe complications, such as eye damage and dysfunciton of salivary glands, have been reported after radiotherapy among patients with head and neck cancer. Complications such as visual impairment have also been reported after proton therapy with pencil beam scanning (PBS). In the case of PBS, collimation can sharpen the penumbra towards surrounding normal tissue in the low energy region of the proton beam. In the current study, we examined how much the dose to the normal tissue was reduced by when intensity-modulated proton therapy (IMPT) was performed using a multi-leaf collimator (MLC) for patients with maxillary sinus cancer. Methods: Computed tomography findings of 26 consecutive patients who received photon therapy at Okayama University Hospital were used in this study. We compared D2% of the region of interest (ROI; ROI-D2%) and the mean dose of ROI (ROI-mean) with and without the use of an MLC. The organs at risk (OARs) were the posterior retina, lacrimal gland, eyeball, and parotid gland. IMPT was performed for all patients. The spot size was approximately 5-6 mm at the isocenter. The collimator margin was calculated by enlarging the maximum outline of the target from the beam's eye view and setting the margin to 6 mm. All plans were optimized with the same parameters. Results: The mean of ROI-D2% for the ipsilateral optic nerve was significantly reduced by 0.48 Gy, and the mean of ROI-mean for the ipsilateral optic nerve was significantly reduced by 1.04 Gy. The mean of ROI-mean to the optic chiasm was significantly reduced by 0.70 Gy. The dose to most OARs and the planning at risk volumes were also reduced. Conclusions: Compared with the plan involving IMPT without an MLC, in the dose plan involving IMPT using an MLC for maxillary sinus cancer, the dose to the optic nerve and optic chiasm were significantly reduced, as measured by the ROI-D2% and the ROI-mean. These findings demonstrate that the use of an MLC during IMPT for maxillary sinus cancer may be useful for preserving vision and preventing complications.
KW - Chemoradiotherapy
KW - Intensity-modulated proton therapy
KW - Maxillary sinus cancer
KW - Multi-leaf collimator
KW - Pencil beam scanning
UR - http://www.scopus.com/inward/record.url?scp=85075539563&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85075539563&partnerID=8YFLogxK
U2 - 10.1186/s13014-019-1405-y
DO - 10.1186/s13014-019-1405-y
M3 - Article
C2 - 31752928
AN - SCOPUS:85075539563
SN - 1748-717X
VL - 14
JO - Radiation Oncology
JF - Radiation Oncology
IS - 1
M1 - 209
ER -