T1 - Early and frequent defibrillator discharge in patients with cardiac sarcoidosis compared with patients with idiopathic dilated cardiomyopathy
AU - Takaya, Yoichi
AU - Kusano, Kengo
AU - Nishii, Nobuhiro
AU - Nakamura, Kazufumi
AU - Ito, Hiroshi
PY - 2017/8/1
Y1 - 2017/8/1
N2 - Background Little is known about the suitability of implantable cardioverter defibrillator (ICD) implantation in patients with cardiac sarcoidosis (CS). We evaluated the efficacy of ICD implantation in patients with CS, including suspected CS, compared with those with idiopathic dilated cardiomyopathy (DCM). Methods A total of 102 consecutive patients with definite CS, suspected CS, or DCM who underwent ICD implantation were enrolled. The endpoint was the first documentation of appropriate ICD therapy for ventricular tachyarrhythmias. The follow-up started after ICD implantation. Results Appropriate ICD therapies occurred in 15 (56%) of 27 patients with definite CS, 17 (68%) of 25 with suspected CS, and 16 (32%) of 50 with DCM. The rate of appropriate ICD therapies was higher in patients with definite CS and those with suspected CS than in those with DCM (log-rank test, p = 0.010). After ICD implantation, five or more appropriate ICD therapies occurred in 5 (19%) patients with definite CS and 10 (40%) with suspected CS, but in only 1 (2%) with DCM. Cox proportional hazard analysis showed that CS, including suspected CS, was independently associated with appropriate ICD therapies. For primary prevention, the rate of appropriate ICD therapies was higher in patients with CS than in those with DCM (log-rank test, p = 0.034). More than half of patients with CS received appropriate ICD therapies. Conclusions Patients with CS receive appropriate ICD therapies for ventricular tachyarrhythmias at a higher rate, compared with those with DCM, suggesting that ICD implantation should be performed in patients with CS.
AB - Background Little is known about the suitability of implantable cardioverter defibrillator (ICD) implantation in patients with cardiac sarcoidosis (CS). We evaluated the efficacy of ICD implantation in patients with CS, including suspected CS, compared with those with idiopathic dilated cardiomyopathy (DCM). Methods A total of 102 consecutive patients with definite CS, suspected CS, or DCM who underwent ICD implantation were enrolled. The endpoint was the first documentation of appropriate ICD therapy for ventricular tachyarrhythmias. The follow-up started after ICD implantation. Results Appropriate ICD therapies occurred in 15 (56%) of 27 patients with definite CS, 17 (68%) of 25 with suspected CS, and 16 (32%) of 50 with DCM. The rate of appropriate ICD therapies was higher in patients with definite CS and those with suspected CS than in those with DCM (log-rank test, p = 0.010). After ICD implantation, five or more appropriate ICD therapies occurred in 5 (19%) patients with definite CS and 10 (40%) with suspected CS, but in only 1 (2%) with DCM. Cox proportional hazard analysis showed that CS, including suspected CS, was independently associated with appropriate ICD therapies. For primary prevention, the rate of appropriate ICD therapies was higher in patients with CS than in those with DCM (log-rank test, p = 0.034). More than half of patients with CS received appropriate ICD therapies. Conclusions Patients with CS receive appropriate ICD therapies for ventricular tachyarrhythmias at a higher rate, compared with those with DCM, suggesting that ICD implantation should be performed in patients with CS.
KW - Cardiac sarcoidosis
KW - Implantable cardioverter defibrillator
KW - Primary prevention
KW - Ventricular tachyarrhythmia
UR - http://www.scopus.com/inward/record.url?scp=85018661140&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85018661140&partnerID=8YFLogxK
U2 - 10.1016/j.ijcard.2017.04.044
DO - 10.1016/j.ijcard.2017.04.044
M3 - Article
C2 - 28438355
AN - SCOPUS:85018661140
SN - 0167-5273
VL - 240
SP - 302
EP - 306
JO - International Journal of Cardiology
JF - International Journal of Cardiology
ER -