TY - JOUR
T1 - Efficacy of shear wave elastography for assessment of liver function in patients with heart failure
AU - Nakayama, Rie
AU - Takaya, Yoichi
AU - Nakamura, Kazufumi
AU - Toh, Norihisa
AU - Itoh, Hiroshi
N1 - Publisher Copyright:
© 2021 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology.
PY - 2021/6
Y1 - 2021/6
N2 - Aims: Liver dysfunction is important for prognosis in heart failure (HF). Shear wave elastography (SWE), which is a novel ultrasound technique for charactering tissues, has been used in liver diseases. However, clinical implication of SWE, including dispersion slope, remains unknown in heart diseases. This study aimed to evaluate the efficacy of SWE assessing liver function in the severity of HF. Methods and results: We enrolled 316 consecutive patients with or suspected heart diseases, who were classified according to the American College of Cardiology Foundation/American Heart Association stage of HF, including 37 with Stage A, 139 with Stage B, 114 with Stage C, and 26 with Stage D, and 45 normal subjects. Elasticity and dispersion slope of shear wave were assessed according to the HF stage. Elasticity and dispersion slope were not elevated in normal subjects and patients with Stage A. Elasticity was slightly increased from Stage A to Stage C and was remarkably elevated in Stage D (normal: 5.2 ± 1.1 kPa, Stage A: 5.4 ± 1.2 kPa, Stage B: 6.4 ± 1.8 kPa, Stage C: 7.8 ± 3.5 kPa, and Stage D: 17.7 ± 12.7 kPa), whereas dispersion slope was gradually increased from Stage A to Stage D (normal: 9.7 ± 1.7m/s/kHz, Stage A: 10.4 ± 1.6m/s/kHz, Stage B: 11.7 ± 2.4m/s/kHz, Stage C: 13.2 ± 3.4m/s/kHz, and Stage D: 17.6 ± 5.6 m/s/kHz). In the early HF stage, dispersion slope was elevated. In the advanced HF stage, both elasticity and dispersion slope were elevated. Liver function test abnormalities were observed only from Stage C or Stage D. Conclusions: Dispersion slope could detect early liver damage, and the combination of elasticity and dispersion slope could clarify the progression of liver dysfunction in HF. SWE may be valuable to manage therapeutic strategies in patients with HF.
AB - Aims: Liver dysfunction is important for prognosis in heart failure (HF). Shear wave elastography (SWE), which is a novel ultrasound technique for charactering tissues, has been used in liver diseases. However, clinical implication of SWE, including dispersion slope, remains unknown in heart diseases. This study aimed to evaluate the efficacy of SWE assessing liver function in the severity of HF. Methods and results: We enrolled 316 consecutive patients with or suspected heart diseases, who were classified according to the American College of Cardiology Foundation/American Heart Association stage of HF, including 37 with Stage A, 139 with Stage B, 114 with Stage C, and 26 with Stage D, and 45 normal subjects. Elasticity and dispersion slope of shear wave were assessed according to the HF stage. Elasticity and dispersion slope were not elevated in normal subjects and patients with Stage A. Elasticity was slightly increased from Stage A to Stage C and was remarkably elevated in Stage D (normal: 5.2 ± 1.1 kPa, Stage A: 5.4 ± 1.2 kPa, Stage B: 6.4 ± 1.8 kPa, Stage C: 7.8 ± 3.5 kPa, and Stage D: 17.7 ± 12.7 kPa), whereas dispersion slope was gradually increased from Stage A to Stage D (normal: 9.7 ± 1.7m/s/kHz, Stage A: 10.4 ± 1.6m/s/kHz, Stage B: 11.7 ± 2.4m/s/kHz, Stage C: 13.2 ± 3.4m/s/kHz, and Stage D: 17.6 ± 5.6 m/s/kHz). In the early HF stage, dispersion slope was elevated. In the advanced HF stage, both elasticity and dispersion slope were elevated. Liver function test abnormalities were observed only from Stage C or Stage D. Conclusions: Dispersion slope could detect early liver damage, and the combination of elasticity and dispersion slope could clarify the progression of liver dysfunction in HF. SWE may be valuable to manage therapeutic strategies in patients with HF.
KW - Dispersion slope
KW - Elasticity
KW - Heart failure
KW - Liver dysfunction
KW - Shear wave elastography
UR - http://www.scopus.com/inward/record.url?scp=85102933141&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85102933141&partnerID=8YFLogxK
U2 - 10.1002/ehf2.13318
DO - 10.1002/ehf2.13318
M3 - Article
C2 - 33760377
AN - SCOPUS:85102933141
SN - 2055-5822
VL - 8
SP - 1751
EP - 1758
JO - ESC heart failure
JF - ESC heart failure
IS - 3
ER -