TY - JOUR
T1 - Hemodynamic monitoring of large animal chronic studies after median sternotomy
T2 - Experiences with different telemetric physiological devices
AU - Fujii, Yasuhiro
AU - Pitsillides, Koullis
AU - Ferro, Giuseppe
AU - Kagawa, Hiroshi
AU - Centola, Luca
AU - Kinouchi, Katsushi
AU - Zhu, Liqun
AU - Ferrier, William T.
AU - Talken, Linda
AU - Nasirov, Teimour
AU - Riemer, R. Kirk
AU - Reinhartz, Olaf
PY - 2015/7/20
Y1 - 2015/7/20
N2 - Telemetric physiological monitoring systems (TPMS) have enabled accurate continuous measurement of animal blood pressures and flows. However, few studies describe approaches for use of TPMS in the great vessels or inside the heart. We describe our initial experiences using two types of TPMSs. Twelve lambs (20-37 kg) underwent sternotomy. Two lambs were not instrumented and were killed at 14 days to confirm normal sternal wound healing (sham group, n = 2). Ten lambs underwent placement of either standard indwelling pressure-monitoring catheter and perivascular-flow-probe (CFP group, n = 3) or TPMS implantation (TPMS group, n = 7). The TPMS used were EG1-V3S2T-M2 (EG1, n = 5; Transonic Endogear Inc.) and Physio Tel Digital L21 (PTD, n = 2; Data Sciences Inc.). Two deaths because of respiratory problems occurred in TPMS group, attributed to lung compression by the implanted device. In TPMS group, more consistent trends of blood pressures and flows were recorded, and management of animals was easier and less labor-intensive. Comparing the two TPMSs, the initiation and renewal costs for each case was $28 K vs. $20 K and $1,700 vs. $0, (PTD versus EG1, respectively). In conclusion, TPMS implantation was feasible via median sternotomy in lambs. Telemetric physiological monitoring systems significantly improve reliability of hemodynamic monitoring in chronic survival animal study. EG1 was less costly than PTD.
AB - Telemetric physiological monitoring systems (TPMS) have enabled accurate continuous measurement of animal blood pressures and flows. However, few studies describe approaches for use of TPMS in the great vessels or inside the heart. We describe our initial experiences using two types of TPMSs. Twelve lambs (20-37 kg) underwent sternotomy. Two lambs were not instrumented and were killed at 14 days to confirm normal sternal wound healing (sham group, n = 2). Ten lambs underwent placement of either standard indwelling pressure-monitoring catheter and perivascular-flow-probe (CFP group, n = 3) or TPMS implantation (TPMS group, n = 7). The TPMS used were EG1-V3S2T-M2 (EG1, n = 5; Transonic Endogear Inc.) and Physio Tel Digital L21 (PTD, n = 2; Data Sciences Inc.). Two deaths because of respiratory problems occurred in TPMS group, attributed to lung compression by the implanted device. In TPMS group, more consistent trends of blood pressures and flows were recorded, and management of animals was easier and less labor-intensive. Comparing the two TPMSs, the initiation and renewal costs for each case was $28 K vs. $20 K and $1,700 vs. $0, (PTD versus EG1, respectively). In conclusion, TPMS implantation was feasible via median sternotomy in lambs. Telemetric physiological monitoring systems significantly improve reliability of hemodynamic monitoring in chronic survival animal study. EG1 was less costly than PTD.
KW - pulmonary arterial blood flow
KW - pulmonary artery pressure
KW - sheep
KW - sternotomy
KW - telemetric monitoring
UR - http://www.scopus.com/inward/record.url?scp=84937641339&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84937641339&partnerID=8YFLogxK
U2 - 10.1097/MAT.0000000000000202
DO - 10.1097/MAT.0000000000000202
M3 - Article
C2 - 25635937
AN - SCOPUS:84937641339
SN - 1058-2916
VL - 61
SP - 332
EP - 338
JO - ASAIO Journal
JF - ASAIO Journal
IS - 3
ER -