N2 - Capillary electrophoresis combined with semiconductor laser-induced fluorometry was applied to an immunoassay of human serum albumin. Human serum albumin was labeled with a fluorescent molecule (Cy5), which has an absorption maximum at 649 nm. The labeled albumin was purified by ultrafiltration in order to reduce signals, which are unreacted labeling reagent, product, and fragment products derived therefrom. After the purification, no signal for unreacted labeling reagent and fragment products was detectable in the electropherogram of the labeled albumin. The labeled albumin was then reacted with anti-albumin to form an immunocomplex, which was separated from the excess free albumin. The competitive immunoassay was used in the determination of human serum albumin in a controlled serum sample, using the labeled albumin. The obtained value was found to be 0.21±0.02 mg/ml, which is in good agreement with other known values.
AB - Capillary electrophoresis combined with semiconductor laser-induced fluorometry was applied to an immunoassay of human serum albumin. Human serum albumin was labeled with a fluorescent molecule (Cy5), which has an absorption maximum at 649 nm. The labeled albumin was purified by ultrafiltration in order to reduce signals, which are unreacted labeling reagent, product, and fragment products derived therefrom. After the purification, no signal for unreacted labeling reagent and fragment products was detectable in the electropherogram of the labeled albumin. The labeled albumin was then reacted with anti-albumin to form an immunocomplex, which was separated from the excess free albumin. The competitive immunoassay was used in the determination of human serum albumin in a controlled serum sample, using the labeled albumin. The obtained value was found to be 0.21±0.02 mg/ml, which is in good agreement with other known values.
KW - Human serum albumin
KW - Semi-conductor laser-induced fluorometry
UR - http://www.scopus.com/inward/record.url?scp=0035882747&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035882747&partnerID=8YFLogxK
U2 - 10.1016/S0378-4347(01)00228-6
DO - 10.1016/S0378-4347(01)00228-6
M3 - Article
C2 - 11499487
AN - SCOPUS:0035882747
SN - 0378-4347
VL - 759
SP - 337
EP - 342
JO - Journal of Chromatography B: Biomedical Sciences and Applications
JF - Journal of Chromatography B: Biomedical Sciences and Applications
IS - 2
ER -