T1 - Left ventricular ejection and filling rate measurement based on the automatic edge detection method of ECG-gated blood pool single-photon emission tomography
AU - Higuchi, Takahiro
AU - Taki, Junichi
AU - Nakajima, Kenichi
AU - Kinuya, Seigo
AU - Ikeda, Masatoshi
AU - Namura, Masanobu
AU - Tonami, Norihisa
PY - 2004/9
Y1 - 2004/9
N2 - The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data. Methods: Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera. From the left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG-gating during the equilibrium state. SPET GBP was conducted utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees by 60 sec per view, in 16 frames/cardiac cycle. In each frame, left ventricular volume was determined by automatic edge detection employing a quantitative gated SPET program. Additionally, the time-volume curve was fitted by the 4th harmonics of Fourier transform. Ejection fraction (EF, %), peak ejection rate (PER,/sec), peak filling rate (PFR,/sec) and mean filling rate during the initial one-third of diastolic time (1/3 FRm) were calculated from the fitted curve. These parameters were also calculated with planar GBP data. Result: Left ventricular ejection and filling parameters were calculated by SPET GBP with the automatic edge detection program for all patient data. Correlation coefficients of EF, PER, PFR and 1/3 FRm between SPET and planar GBP were 0.91 (p < 0.001), 0.82 (p < 0.001), 0.78 (p < 0.001) and 0.74 (p < 0.001), respectively. Conclusion: Ejection and filling rates can be calculated using SPET GBP with the edge-detection software. These parameters displayed significant correlations with those values obtained via planar GBP. Additional studies are warranted to determine the reliability of parameters with SPET GBP.
AB - The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data. Methods: Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera. From the left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG-gating during the equilibrium state. SPET GBP was conducted utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees by 60 sec per view, in 16 frames/cardiac cycle. In each frame, left ventricular volume was determined by automatic edge detection employing a quantitative gated SPET program. Additionally, the time-volume curve was fitted by the 4th harmonics of Fourier transform. Ejection fraction (EF, %), peak ejection rate (PER,/sec), peak filling rate (PFR,/sec) and mean filling rate during the initial one-third of diastolic time (1/3 FRm) were calculated from the fitted curve. These parameters were also calculated with planar GBP data. Result: Left ventricular ejection and filling parameters were calculated by SPET GBP with the automatic edge detection program for all patient data. Correlation coefficients of EF, PER, PFR and 1/3 FRm between SPET and planar GBP were 0.91 (p < 0.001), 0.82 (p < 0.001), 0.78 (p < 0.001) and 0.74 (p < 0.001), respectively. Conclusion: Ejection and filling rates can be calculated using SPET GBP with the edge-detection software. These parameters displayed significant correlations with those values obtained via planar GBP. Additional studies are warranted to determine the reliability of parameters with SPET GBP.
KW - Blood pool scintigraphy
KW - Ejection fraction
KW - Ejection rate
KW - Filling rate
KW - Gated SPET
UR - http://www.scopus.com/inward/record.url?scp=6944230709&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=6944230709&partnerID=8YFLogxK
U2 - 10.1007/BF02984568
DO - 10.1007/BF02984568
M3 - Article
C2 - 15515751
AN - SCOPUS:6944230709
SN - 0914-7187
VL - 18
SP - 507
EP - 511
JO - Annals of nuclear medicine
JF - Annals of nuclear medicine
IS - 6
ER -