Abstract
The objective of the present investigation was to determine the feasibility of assessing left ventricular systolic ejection and diastolic filling via the automatic edge detection method employing ECG-gated blood pool single-photon emission tomography (SPET GBP) data. Methods: Thirty-five patients, who had undergone both SPET GBP and ECG-gated equilibrium blood pool scintigraphy by the planar method (planar GBP), were enrolled in this study. Planar GBP was performed with a single-headed gamma camera. From the left anterior oblique projection, data were acquired at 24 frames/cardiac cycle with ECG-gating during the equilibrium state. SPET GBP was conducted utilizing a triple-headed gamma camera, with 60 projection views over 360 degrees by 60 sec per view, in 16 frames/cardiac cycle. In each frame, left ventricular volume was determined by automatic edge detection employing a quantitative gated SPET program. Additionally, the time-volume curve was fitted by the 4th harmonics of Fourier transform. Ejection fraction (EF, %), peak ejection rate (PER,/sec), peak filling rate (PFR,/sec) and mean filling rate during the initial one-third of diastolic time (1/3 FRm) were calculated from the fitted curve. These parameters were also calculated with planar GBP data. Result: Left ventricular ejection and filling parameters were calculated by SPET GBP with the automatic edge detection program for all patient data. Correlation coefficients of EF, PER, PFR and 1/3 FRm between SPET and planar GBP were 0.91 (p < 0.001), 0.82 (p < 0.001), 0.78 (p < 0.001) and 0.74 (p < 0.001), respectively. Conclusion: Ejection and filling rates can be calculated using SPET GBP with the edge-detection software. These parameters displayed significant correlations with those values obtained via planar GBP. Additional studies are warranted to determine the reliability of parameters with SPET GBP.
| Original language | English |
|---|---|
| Pages (from-to) | 507-511 |
| Number of pages | 5 |
| Journal | Annals of nuclear medicine |
| Volume | 18 |
| Issue number | 6 |
| DOIs | |
| Publication status | Published - Sept 2004 |
| Externally published | Yes |
Keywords
- Blood pool scintigraphy
- Ejection fraction
- Ejection rate
- Filling rate
- Gated SPET
ASJC Scopus subject areas
- Radiology Nuclear Medicine and imaging
Fingerprint
Dive into the research topics of 'Left ventricular ejection and filling rate measurement based on the automatic edge detection method of ECG-gated blood pool single-photon emission tomography'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS