TY - JOUR
T1 - Newly designed flat surface artificial tongue system for speech improvement in glossectomy patients
T2 - A preliminary study
AU - Nagatsuka, Hiroaki
AU - Kawakami, Shigehisa
AU - Kuwahara, Miho
AU - Kubota, Chie
AU - Kodama, Naoki
AU - Minagi, Shogo
N1 - Publisher Copyright:
© 2021 Japan Prosthodontic Society. All rights reserved.
PY - 2022
Y1 - 2022
N2 - Purpose: To design an efficient tongue prosthesis with reproducibility and to objectively evaluate improvement in speech function. Methods: A silicon anatomical artificial tongue (AT) and a flat surface artificial tongue system (FTS) were used in our study. Twenty healthy participants (10 males and 10 females, 26.3 ± 1.8 years) were fitted with a tongue movement suppression appliance (TSA) that fit the dental arch to simulate the glossectomy condition. TSA, TSA + FTS, and TSA + AT simulated the state of glossectomy patients without artificial tongue, with normal artificial tongue, and newly designed artificial tongue, respectively. Three speech intelligibility tests were performed for each of the following conditions: pronouncing 100 Japanese monosyllables, 40 Japanese words, and reading a short story. One-way ANOVA, Wilcoxon signed-rank test, and Tukey-Kramer post-hoc test were used for statistical analyses. Results: Significant differences were observed for 100 Japanese monosyllables and 40 Japanese words between the TSA + FTS, TSA, and TSA + AT conditions (p < 0.05). Regarding the speech intelligibility test for reading a short story, the TSA + FTS condition resulted in a significantly higher speech intelligibility than the TSA and TSA + AT conditions (p < 0.05). Conclusion: A flat surface artificial tongue system contributed to the improvement in speech function. This structure can be easily used in cases where conventional artificial tongue are applicable, regardless of variation in the oral condition; thus, making it a widely applicable treatment option for glossectomy patients.
AB - Purpose: To design an efficient tongue prosthesis with reproducibility and to objectively evaluate improvement in speech function. Methods: A silicon anatomical artificial tongue (AT) and a flat surface artificial tongue system (FTS) were used in our study. Twenty healthy participants (10 males and 10 females, 26.3 ± 1.8 years) were fitted with a tongue movement suppression appliance (TSA) that fit the dental arch to simulate the glossectomy condition. TSA, TSA + FTS, and TSA + AT simulated the state of glossectomy patients without artificial tongue, with normal artificial tongue, and newly designed artificial tongue, respectively. Three speech intelligibility tests were performed for each of the following conditions: pronouncing 100 Japanese monosyllables, 40 Japanese words, and reading a short story. One-way ANOVA, Wilcoxon signed-rank test, and Tukey-Kramer post-hoc test were used for statistical analyses. Results: Significant differences were observed for 100 Japanese monosyllables and 40 Japanese words between the TSA + FTS, TSA, and TSA + AT conditions (p < 0.05). Regarding the speech intelligibility test for reading a short story, the TSA + FTS condition resulted in a significantly higher speech intelligibility than the TSA and TSA + AT conditions (p < 0.05). Conclusion: A flat surface artificial tongue system contributed to the improvement in speech function. This structure can be easily used in cases where conventional artificial tongue are applicable, regardless of variation in the oral condition; thus, making it a widely applicable treatment option for glossectomy patients.
KW - Artificial tongue
KW - Glossectomy
KW - Speech intelligibility
KW - Tongue suppression
KW - Tongue tumor
UR - http://www.scopus.com/inward/record.url?scp=85123457899&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85123457899&partnerID=8YFLogxK
U2 - 10.2186/jpr.JPR_D_20_00230
DO - 10.2186/jpr.JPR_D_20_00230
M3 - Article
C2 - 34261846
AN - SCOPUS:85123457899
SN - 1883-1958
VL - 66
SP - 87
EP - 92
JO - Nippon Hotetsu Shika Gakkai zasshi
JF - Nippon Hotetsu Shika Gakkai zasshi
IS - 1
ER -