Abstract
We have fabricated a first-order, directly coupled gradiometer with a gradiometric balance below 0.1% without balance adjustment by selecting the coupling direction of the pickup coil and the superconducting quantum interference device. The noise of the gradiometers with various balances measured in an unshielded environment decreased in proportion to the improvement in balance. However, the noise of the gradiometer with a balance of 0.03% was limited by the gradient field component of the environmental noise. Magnetocardiogram measurement with this gradiometer in an unshielded environment was also demonstrated.
Original language | English |
---|---|
Pages (from-to) | 41-44 |
Number of pages | 4 |
Journal | Physica C: Superconductivity and its applications |
Volume | 368 |
Issue number | 1-4 |
DOIs | |
Publication status | Published - Mar 1 2002 |
Externally published | Yes |
Keywords
- Gradiometer
- SQUID
- YBaCuO
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Energy Engineering and Power Technology
- Electrical and Electronic Engineering