TY - JOUR
T1 - Nonthermal effects of mobile-phone frequency microwaves on uteroplacental functions in pregnant rats
AU - Nakamura, Hiroyuki
AU - Matsuzaki, Ichiyo
AU - Hatta, Kotaro
AU - Nobukuni, Yoshitaka
AU - Kambayashi, Yasuhiro
AU - Ogino, Keiki
N1 - Funding Information:
This work was supported in part by a Grant-in Aid for Scientific Research (B; No. 09670382, B; No. 13470079) from the ministry of Education, Sports, Science and Culture of Japan for 2000–2002.
PY - 2003
Y1 - 2003
N2 - Exposure to high-density microwaves can cause detrimental effects on the testis, eye, and other tissues, and induce significant biologic changes through thermal actions. To examine nonthermal effect of continuous wave (CW) 915 MHz microwaves used in cellular phones, we compared the effects of microwaves with those of heat. Thirty-six pregnant rats were assigned to six groups: rats exposed to microwaves at 0.6 or 3 mW/cm2 incident power density at 915 MHz for 90 min, rats immersed in water at 38 or 40 °C, which induces about the same increase in colonic temperature of 1.0 or 3.5 °C as 0.6 or 3 mW/cm2 microwaves, respectively; rats immersed in water at 34 °C, which is considered to be thermoneutral; and control rats. We identified significant differences in the uteroplacental circulation, and in placental endocrine and immune functions between pregnant rats immersed in water at 34 and 38 °C, but not between rats immersed at 38 °C and those exposed to microwaves at 0.6 mW/cm2. By contrast, we observed significant decreases in uteroplacental blood flow and estradiol in rats exposed to microwaves at 3 mW/cm2 as compared with those immersed in water at 40 °C. These results suggest microwaves at 0.6 mW/cm2 at 915 MHz, equal to a specific absorption rate (SAR) of 0.4 W/kg, which is the maximum permissible exposure level recommended by the American National Standards Institute (ANSI), do not exert nonthermal effects on blood estradiol and progesterone, on splenic natural killer cell activity, on the uteroplacental circulation.
AB - Exposure to high-density microwaves can cause detrimental effects on the testis, eye, and other tissues, and induce significant biologic changes through thermal actions. To examine nonthermal effect of continuous wave (CW) 915 MHz microwaves used in cellular phones, we compared the effects of microwaves with those of heat. Thirty-six pregnant rats were assigned to six groups: rats exposed to microwaves at 0.6 or 3 mW/cm2 incident power density at 915 MHz for 90 min, rats immersed in water at 38 or 40 °C, which induces about the same increase in colonic temperature of 1.0 or 3.5 °C as 0.6 or 3 mW/cm2 microwaves, respectively; rats immersed in water at 34 °C, which is considered to be thermoneutral; and control rats. We identified significant differences in the uteroplacental circulation, and in placental endocrine and immune functions between pregnant rats immersed in water at 34 and 38 °C, but not between rats immersed at 38 °C and those exposed to microwaves at 0.6 mW/cm2. By contrast, we observed significant decreases in uteroplacental blood flow and estradiol in rats exposed to microwaves at 3 mW/cm2 as compared with those immersed in water at 40 °C. These results suggest microwaves at 0.6 mW/cm2 at 915 MHz, equal to a specific absorption rate (SAR) of 0.4 W/kg, which is the maximum permissible exposure level recommended by the American National Standards Institute (ANSI), do not exert nonthermal effects on blood estradiol and progesterone, on splenic natural killer cell activity, on the uteroplacental circulation.
KW - Cellular phones
KW - Estradiol
KW - Microwave
KW - Natural killer cell activity
KW - Pregnancy
KW - Progesterone
KW - Thermal effect
KW - Uteroplacental blood flow
UR - http://www.scopus.com/inward/record.url?scp=0038823649&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038823649&partnerID=8YFLogxK
U2 - 10.1016/S0890-6238(03)00010-8
DO - 10.1016/S0890-6238(03)00010-8
M3 - Article
C2 - 12759101
AN - SCOPUS:0038823649
SN - 0890-6238
VL - 17
SP - 321
EP - 326
JO - Reproductive Toxicology
JF - Reproductive Toxicology
IS - 3
ER -