TY - JOUR
T1 - Protection System for Normal Transitions in a Single-phase Bi2223 Full Superconducting Transformer by the Active Power Method under Flowing Currents of Various Frequencies
AU - Nanato, N.
AU - Ono, T.
AU - Adachi, T.
AU - Yamanishi, T.
N1 - Funding Information:
This work was supported by Electric Technology Research Foundation of Chugoku.
Publisher Copyright:
© Published under licence by IOP Publishing Ltd.
PY - 2018/7/26
Y1 - 2018/7/26
N2 - The authors have developed a large AC current supply with a single-phase Bi2223 full superconducting transformer. The supply is very small and light and can output currents of various values and frequencies. In order to operate the supply safely, a protection system for normal transitions in the transformer is essential. The authors have proposed the system based on the active power method, which detects the normal transitions as dissipated active power in the normal area. Previous studies have shown that the protection system can work well for the transformer in transporting constant current of 60 Hz. The supply is used under transporting currents of various values and frequencies. AC loss and iron loss in the transformer are increased by increasing the value and frequency and then they are detected as active power in a superconducting state. Therefore these losses cause incorrect recognition of the normal transitions. In this paper, the authors propose the system which can detect correctly the normal transitions regardless of the losses. The experimental results show its usefulness for the transformer.
AB - The authors have developed a large AC current supply with a single-phase Bi2223 full superconducting transformer. The supply is very small and light and can output currents of various values and frequencies. In order to operate the supply safely, a protection system for normal transitions in the transformer is essential. The authors have proposed the system based on the active power method, which detects the normal transitions as dissipated active power in the normal area. Previous studies have shown that the protection system can work well for the transformer in transporting constant current of 60 Hz. The supply is used under transporting currents of various values and frequencies. AC loss and iron loss in the transformer are increased by increasing the value and frequency and then they are detected as active power in a superconducting state. Therefore these losses cause incorrect recognition of the normal transitions. In this paper, the authors propose the system which can detect correctly the normal transitions regardless of the losses. The experimental results show its usefulness for the transformer.
UR - http://www.scopus.com/inward/record.url?scp=85051337120&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85051337120&partnerID=8YFLogxK
U2 - 10.1088/1742-6596/1054/1/012068
DO - 10.1088/1742-6596/1054/1/012068
M3 - Conference article
AN - SCOPUS:85051337120
SN - 1742-6588
VL - 1054
JO - Journal of Physics: Conference Series
JF - Journal of Physics: Conference Series
IS - 1
M1 - 012068
T2 - 30th International Symposium on Superconductivity, ISS 2017
Y2 - 13 December 2017 through 15 December 2017
ER -