TY - JOUR
T1 - Radiologic removal and replacement of port-catheter systems for hepatic arterial infusion chemotherapy
AU - Iguchi, Toshihiro
AU - Inaba, Yoshitaka
AU - Arai, Yasuaki
AU - Yamaura, Hidekazu
AU - Sato, Yozo
AU - Miyazaki, Masaya
AU - Shimamoto, Hiroshi
AU - Hayashi, Takayuki
PY - 2006/12/1
Y1 - 2006/12/1
N2 - OBJECTIVE. The purpose of our study was to retrospectively evaluate the safety and efficacy of radiologic removal and replacement of port-catheter systems. MATERIALS AND METHODS. Between January 1999 and December 2004, 532 patients with unresectable advanced liver cancer underwent radiologic placement of port-catheter systems at our institution. Of these, 18 patients (nine men and nine women; age range, 32-83 years; mean age, 53.8 years) underwent removal of an implanted port-catheter system via the right femoral artery and radiographically guided replacement with a new system to allow continuous hepatic arterial infusion chemotherapy; we retrospectively reviewed these 18 cases. The reasons for removal of the previously implanted systems were as follows: catheter dislodgement (n = 15), catheter obstruction (n = 1), infection related to the implanted port (n = 1), and hemodynamic change (n = 1). Digital subtraction angiography and CT were performed, usually during injection of contrast medium through the implanted port-catheter system, within a few days after the replacement procedure and every 3 months thereafter. RESULTS. We successfully performed radiologic removal and replacement of the port-catheter system while the patient was under local anesthesia in all 18 patients without complications requiring treatment. The cumulative patency rates of the hepatic artery after removal of the old port-catheter system and replacement with a new port-catheter system were 87.8% and 64.1% at 6 months and 1 year, respectively. Hepatic arterial infusion chemotherapy after replacement was performed 0-68 times (median, 19 times). CONCLUSION. When an implanted port-catheter system can no longer be used but the patency of the hepatic artery is confirmed and continuous hepatic arterial infusion chemotherapy is required, removal and replacement of the port-catheter system are recommended.
AB - OBJECTIVE. The purpose of our study was to retrospectively evaluate the safety and efficacy of radiologic removal and replacement of port-catheter systems. MATERIALS AND METHODS. Between January 1999 and December 2004, 532 patients with unresectable advanced liver cancer underwent radiologic placement of port-catheter systems at our institution. Of these, 18 patients (nine men and nine women; age range, 32-83 years; mean age, 53.8 years) underwent removal of an implanted port-catheter system via the right femoral artery and radiographically guided replacement with a new system to allow continuous hepatic arterial infusion chemotherapy; we retrospectively reviewed these 18 cases. The reasons for removal of the previously implanted systems were as follows: catheter dislodgement (n = 15), catheter obstruction (n = 1), infection related to the implanted port (n = 1), and hemodynamic change (n = 1). Digital subtraction angiography and CT were performed, usually during injection of contrast medium through the implanted port-catheter system, within a few days after the replacement procedure and every 3 months thereafter. RESULTS. We successfully performed radiologic removal and replacement of the port-catheter system while the patient was under local anesthesia in all 18 patients without complications requiring treatment. The cumulative patency rates of the hepatic artery after removal of the old port-catheter system and replacement with a new port-catheter system were 87.8% and 64.1% at 6 months and 1 year, respectively. Hepatic arterial infusion chemotherapy after replacement was performed 0-68 times (median, 19 times). CONCLUSION. When an implanted port-catheter system can no longer be used but the patency of the hepatic artery is confirmed and continuous hepatic arterial infusion chemotherapy is required, removal and replacement of the port-catheter system are recommended.
KW - Chemotherapy
KW - Implantable devices
KW - Liver cancer
KW - Port-catheter system
UR - http://www.scopus.com/inward/record.url?scp=33751236215&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33751236215&partnerID=8YFLogxK
U2 - 10.2214/AJR.05.0646
DO - 10.2214/AJR.05.0646
M3 - Article
C2 - 17114553
AN - SCOPUS:33751236215
SN - 0361-803X
VL - 187
SP - 1579
EP - 1584
JO - The American journal of roentgenology and radium therapy
JF - The American journal of roentgenology and radium therapy
IS - 6
ER -