TY - JOUR
T1 - Technique, cell assembly, and measurement of T- dependent electrical resistivity of liquid Fe devoid of contamination at P, T conditions
AU - Ezenwa, Innocent
AU - Yoshino, Takashi
N1 - Funding Information:
This work was supported by the Ministry of Education, Culture, Sports, Science, and Technology of the Japanese Government (Grant Nos. 15H05827 and 17H01155) to T.Y. The authors sincerely thank the anonymous reviewers for their immense contributions in improving this manuscript.
Publisher Copyright:
© 2020 Author(s).
PY - 2020/2/1
Y1 - 2020/2/1
N2 - Since the cores of rocky planetary bodies are mainly Fe in composition, the understanding of the electrical resistivity and thermal conductivity of solid and molten Fe at pressure and temperature conditions is vital in placing a constraint on the quantity of heat flux from the cores of these planets. We develop an experimental technique and cell design to measure the temperature-dependent electrical resistivity of solid and molten Fe and other transition metals under high pressure. This addresses the problem of metal sample contamination encountered in designs that used W/Re, W, and Mo in direct contact with the sample. At first, we attempted to improve these pre-existing designs by testing the suitability of Hf and Zr metals to serve as a mechanical barrier between the electrodes and the sample. Unfortunately, our result shows that solid Hf and Zr dissolve in molten Fe and are not suitable for this purpose. Next, we adopt the same sample material, Fe, for electrodes and leads while the thermocouple leads are taken through the gasket and protected against frequent mechanical breakage using the shielding technique. The recovered Fe samples compressed at various pressure conditions and heated up to 200 K above the melting temperature show no trace of contamination. As anticipated, the resistivity increases and decreases with increasing temperature and pressure, respectively. Thus, to closely measure the electrical resistivity of molten Fe and other similar metals at extreme conditions, it is necessary to ensure liquid containment, eliminate biased voltage through the current reversal technique, and ensure the use of the same material for the electrode and sample while monitoring the sample temperature using a thermocouple placed close to but not in contact with the sample. Our developed technique provides the highly demanding technique for investigating the temperature-dependent electrical resistivity of Fe and other similar metals devoid of contamination at extreme conditions. This progress will accelerate studies which will provide a detailed understanding of the electrical and heat transport properties of Fe as it applies to the core of rocky planetary bodies.
AB - Since the cores of rocky planetary bodies are mainly Fe in composition, the understanding of the electrical resistivity and thermal conductivity of solid and molten Fe at pressure and temperature conditions is vital in placing a constraint on the quantity of heat flux from the cores of these planets. We develop an experimental technique and cell design to measure the temperature-dependent electrical resistivity of solid and molten Fe and other transition metals under high pressure. This addresses the problem of metal sample contamination encountered in designs that used W/Re, W, and Mo in direct contact with the sample. At first, we attempted to improve these pre-existing designs by testing the suitability of Hf and Zr metals to serve as a mechanical barrier between the electrodes and the sample. Unfortunately, our result shows that solid Hf and Zr dissolve in molten Fe and are not suitable for this purpose. Next, we adopt the same sample material, Fe, for electrodes and leads while the thermocouple leads are taken through the gasket and protected against frequent mechanical breakage using the shielding technique. The recovered Fe samples compressed at various pressure conditions and heated up to 200 K above the melting temperature show no trace of contamination. As anticipated, the resistivity increases and decreases with increasing temperature and pressure, respectively. Thus, to closely measure the electrical resistivity of molten Fe and other similar metals at extreme conditions, it is necessary to ensure liquid containment, eliminate biased voltage through the current reversal technique, and ensure the use of the same material for the electrode and sample while monitoring the sample temperature using a thermocouple placed close to but not in contact with the sample. Our developed technique provides the highly demanding technique for investigating the temperature-dependent electrical resistivity of Fe and other similar metals devoid of contamination at extreme conditions. This progress will accelerate studies which will provide a detailed understanding of the electrical and heat transport properties of Fe as it applies to the core of rocky planetary bodies.
UR - http://www.scopus.com/inward/record.url?scp=85079223998&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85079223998&partnerID=8YFLogxK
U2 - 10.1063/1.5112045
DO - 10.1063/1.5112045
M3 - Article
C2 - 32113395
AN - SCOPUS:85079223998
SN - 0034-6748
VL - 91
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 2
M1 - 023903
ER -