TY - JOUR
T1 - Technique for single-step lymphocyte isolation from an endoscopic biopsy specimen for the diagnosis of gastrointestinal lymphoma
AU - Iwamuro, Masaya
AU - Takahashi, Takahide
AU - Watanabe, Natsuki
AU - Omote, Sizuma
AU - Matsueda, Katsunori
AU - Tanaka, Takehiro
AU - Ennishi, Daisuke
AU - Otsuka, Fumio
AU - Yoshino, Tadashi
AU - Okada, Hiroyuki
N1 - Publisher Copyright:
© 2020
PY - 2020/1
Y1 - 2020/1
N2 - In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility: 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa. • We introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. • Our technique is feasible for flow cytometric analysis in patients with gastrointestinal lymphoma as well as those with gastrointestinal lesions that are suspected to be lymphoma.
AB - In this paper, we introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. For lymphocyte isolation, an endoscopically harvested specimen and 5 mL of normal saline solution were placed in a wire mesh strainer set in a porcelain bowl. To obtain the lymphocyte suspension, the solid specimen was crushed using the rubber portion of a plunger of a 10 mL injection syringe. Flow cytometry was performed using the lymphocyte suspension. For validating our methods, the one-step lymphocyte isolation technique was used to perform flow cytometry on samples from 23 patients with (n = 12) or without (n = 11) gastrointestinal lymphoma. Flow cytometry of light chain expression was performed in all patient samples (feasibility: 100%). Sensitivity was 83.3% (10/12) and specificity was 100% (11/11). In conclusion, lymphocytes isolated from a single endoscopic biopsy specimen using our simplified and quick procedure are suitable for flow cytometry. Considering that flow cytometry has an important advantage of providing the results on the examination day itself, the results of this study suggest that flow cytometric analysis using our single-step lymphocyte isolation technique can be potentially used to diagnose lymphoma in the gastrointestinal mucosa. • We introduce a simplified, one-step procedure for lymphocyte isolation from an endoscopically biopsied fragment. • Our technique is feasible for flow cytometric analysis in patients with gastrointestinal lymphoma as well as those with gastrointestinal lesions that are suspected to be lymphoma.
KW - Flow cytometry
KW - Gastrointestinal lymphoma
KW - Light chain restriction
KW - Lymphocyte isolation
KW - Single-step lymphocyte isolation from an endoscopic biopsy specimen
UR - http://www.scopus.com/inward/record.url?scp=85092647044&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85092647044&partnerID=8YFLogxK
U2 - 10.1016/j.mex.2020.101095
DO - 10.1016/j.mex.2020.101095
M3 - Article
AN - SCOPUS:85092647044
SN - 2215-0161
VL - 7
JO - MethodsX
JF - MethodsX
M1 - 101095
ER -