TY - JOUR
T1 - Usefulness of 3-dimensional CT angiograms obtained by 64-section multidetector row CT scanner for dural arteriovenous fistula
AU - Nakagawa, Minoru
AU - Sugiu, Kenji
AU - Tokunaga, Koji
AU - Tsuda, Kohei
AU - Imaoka, Matsuhiro
AU - Kawahara, Atsushi
AU - Fujiwara, Kenjiro
PY - 2009/4
Y1 - 2009/4
N2 - The authors reported a case of a dural arteriovenous fistula (DAVF) in the left transverse-sigmoid sinus, in which 3-dimensional computed tomography (CT) angiograms (3D-CTAs) by a 64-section multidetector row CT scanner were useful for its diagnosis and treatment. The DAVF in the left transverse-sigmoid sinus appeared on the digital subtraction angiogram. 3D-CTAs were obtained by a 64-section multidetector row CT scanner before an endovascular treatment. The feeders and draining veins of the DAVF were clearly demonstrated on the 3D-CTAs, which clarified the relationship between the normal dural sinuses and DAVF. The DAVF was successfully treated with endovascular surgery, a transvenous embolization through the mastoid emissary vein, which was easily detected by using the 3D-CTA, showing both the subcutaneous vein and calvalium. 3D-CTAs by a 64-section multidetector row CT scanner are useful for both diagnosis and treatment of DAVFs.
AB - The authors reported a case of a dural arteriovenous fistula (DAVF) in the left transverse-sigmoid sinus, in which 3-dimensional computed tomography (CT) angiograms (3D-CTAs) by a 64-section multidetector row CT scanner were useful for its diagnosis and treatment. The DAVF in the left transverse-sigmoid sinus appeared on the digital subtraction angiogram. 3D-CTAs were obtained by a 64-section multidetector row CT scanner before an endovascular treatment. The feeders and draining veins of the DAVF were clearly demonstrated on the 3D-CTAs, which clarified the relationship between the normal dural sinuses and DAVF. The DAVF was successfully treated with endovascular surgery, a transvenous embolization through the mastoid emissary vein, which was easily detected by using the 3D-CTA, showing both the subcutaneous vein and calvalium. 3D-CTAs by a 64-section multidetector row CT scanner are useful for both diagnosis and treatment of DAVFs.
KW - 3-dimentional
KW - Angiography
KW - CT
KW - Dural arteriovenous fistula
KW - Endovascular embolization
KW - Spiral
UR - http://www.scopus.com/inward/record.url?scp=63149087327&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=63149087327&partnerID=8YFLogxK
U2 - 10.1111/j.1552-6569.2007.00228.x
DO - 10.1111/j.1552-6569.2007.00228.x
M3 - Article
C2 - 18795991
AN - SCOPUS:63149087327
SN - 1051-2284
VL - 19
SP - 179
EP - 182
JO - Journal of Neuroimaging
JF - Journal of Neuroimaging
IS - 2