Utility of a 21-gauge Menghini-type biopsy needle with the rolling method for an endoscopic ultrasound-guided histological diagnosis of autoimmune pancreatitis: a retrospective study

Koichiro Tsutsumi, Toru Ueki, Yasuhiro Noma, Kunihiro Omonishi, Kyotaro Ohno, Soichiro Kawahara, Takashi Oda, Hironari Kato, Hiroyuki Okada

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

Background: The histological diagnosis of autoimmune pancreatitis (AIP) by an endoscopic ultrasound (EUS)-guided approach is still challenging. Methods: We investigated the utility of the 21-gauge Menghini-type biopsy needle with the rolling method for the histological diagnosis of AIP, in comparison with conventional 22-gauge needles. Among total 28 patients, rate of definitive histological diagnosis, acquired sample area of tissue, rate of histopathological diagnosis of AIP, and adverse events were retrospectively analyzed. Results: Definitive histological diagnoses were successfully accomplished in all 14 patients (100%) treated with a Menghini-type needle, and in 57% of cases (8/14) treated with conventional 22-gauge needles (P < 0.001). The median sample area of the tissue, except for blood contamination, was remarkably larger by the Menghini-type needle than by conventional-type needles (6.2 [IQR, 4.5–8.8] versus 0.7 [IQR, 0.2–2.0] mm2, P < 0.001), and the area per punctures was approximately 4 times larger (1.4 [IQR: 0.9–2.9] versus 0.3 [IQR: 0.1–0.6] mm2/puncture, P < 0.001). Based on the International Consensus Diagnostic Criteria, lymphoplasmacytic infiltration, abundant IgG4-postive cells, storiform fibrosis, and obliterative phlebitis were found in 86%/29%, 64%/0%, 36%/0%, and 7%/0% patients who were treated with the Menghini-type needle and conventional-type needles, respectively. Consequently, histopathological diagnosis with type 1 AIP (lever 1 or 2) was achieved in 9 patients (64%) treated with the Menghini-type needle and in no patient treated with conventional-type needles (P < 0.001). Two patients who had mild post-procedural pancreatitis improved with conservative treatment, and no bleeding occurred in patients treated with the Menghini-type needle. Conclusion: EUS-guided rolling method with the 21-gauge Menghini-type biopsy needle is useful for the histopathological diagnosis of AIP, due to its abundant acquisition of good-quality tissue from the pancreas.

Original languageEnglish
Article number21
JournalBMC Gastroenterology
Volume21
Issue number1
DOIs
Publication statusPublished - Dec 2021

Keywords

  • EUS-FNB
  • Good-quality tissue
  • ICDC
  • Sample area

ASJC Scopus subject areas

  • Gastroenterology

Fingerprint

Dive into the research topics of 'Utility of a 21-gauge Menghini-type biopsy needle with the rolling method for an endoscopic ultrasound-guided histological diagnosis of autoimmune pancreatitis: a retrospective study'. Together they form a unique fingerprint.

Cite this