TY - JOUR
T1 - [A comparison of four commercial radiation treatment planning systems for prostate intensity modulated radiation therapy].
AU - Sasaki, Motoharu
AU - Ikushima, Hitoshi
AU - Nakaguchi, Yuji
AU - Kishi, Tarou
AU - Kimura, Masashi
AU - Bandou, Ryouta
AU - Oita, Masataka
PY - 2013/7
Y1 - 2013/7
N2 - At present, every manufacturer of intensity modulated radiation therapy (IMRT) equipment uses multi-leaf collimators (MLCs); however, each company's intensity modulation methods and dose calculation algorithms differ. This study used four typical radiation treatment planning systems (RTPSs) employed domestically for prostate IMRT plans to carry out 15 case studies by one planner based on the dose limits at this clinic. The results were used to compare the differences, if any, in RTPS treatment plans. With prostate IMRT plans, an overlap area exists between the PTV and the rectum. For this reason, while observing dose limits of 60-75 Gy (within the dose tolerated by the rectum), securing uniformity and concentration of dose is essential to create the most appropriate treatment plan for the PTV and other targets. Although each RTPS uses different planning methods, it was generally possible to observe this clinic's dose limits by adjusting the parameter values. When identical beam data is used, it is possible to create similar treatment plans.
AB - At present, every manufacturer of intensity modulated radiation therapy (IMRT) equipment uses multi-leaf collimators (MLCs); however, each company's intensity modulation methods and dose calculation algorithms differ. This study used four typical radiation treatment planning systems (RTPSs) employed domestically for prostate IMRT plans to carry out 15 case studies by one planner based on the dose limits at this clinic. The results were used to compare the differences, if any, in RTPS treatment plans. With prostate IMRT plans, an overlap area exists between the PTV and the rectum. For this reason, while observing dose limits of 60-75 Gy (within the dose tolerated by the rectum), securing uniformity and concentration of dose is essential to create the most appropriate treatment plan for the PTV and other targets. Although each RTPS uses different planning methods, it was generally possible to observe this clinic's dose limits by adjusting the parameter values. When identical beam data is used, it is possible to create similar treatment plans.
UR - http://www.scopus.com/inward/record.url?scp=84891376185&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84891376185&partnerID=8YFLogxK
U2 - 10.6009/jjrt.2013_JSRT_69.7.761
DO - 10.6009/jjrt.2013_JSRT_69.7.761
M3 - Article
C2 - 23877154
AN - SCOPUS:84891376185
SN - 0369-4305
VL - 69
SP - 761
EP - 772
JO - Nihon Hoshasen Gijutsu Gakkai zasshi
JF - Nihon Hoshasen Gijutsu Gakkai zasshi
IS - 7
ER -