TY - JOUR
T1 - A prospective randomized trial comparing the clinical effectiveness and biocompatibility of heparin-coated circuits and PMEA-coated circuits in pediatric cardiopulmonary bypass
AU - Itoh, Hideshi
AU - Ichiba, Shingo
AU - Ujike, Yoshihito
AU - Douguchi, Takuma
AU - Kasahara, Shingo
AU - Arai, Sadahiko
AU - Sano, Shunji
N1 - Publisher Copyright:
© The Author(s) 2015.
PY - 2016/4/1
Y1 - 2016/4/1
N2 - Object: We compared the clinical effectiveness and biocompatibility of poly-2-methoxyethyl acrylate (PMEA)-coated and heparin-coated cardiopulmonary bypass (CPB) circuits in a prospective pediatric trial. Methods: Infants randomly received heparin-coated (n=7) or PMEA-coated (n=7) circuits in elective pediatric cardiac surgery with CPB for ventricular septum defects. Clinical and hematologic variables, respiratory indices and hemodynamic changes were analyzed perioperatively. Results: Demographic and clinical variables were similar in both groups. Leukocyte counts were significantly lower 5 minutes after CPB in the PMEA group than the heparin group. Hemodynamic data showed that PMEA caused hypotension within 5 minutes of CPB. The respiratory index was significantly higher immediately after CPB and 1 hour after transfer to the intensive care unit (ICU) in the PMEA group, as were levels of C-reactive protein 24 hours after transfer to the ICU. Conclusion: Our study shows that PMEA-coated circuits, unlike heparin-coated circuits, cause transient leukopenia during pediatric CPB and, perhaps, systemic inflammatory respiratory syndrome after pediatric CPB.
AB - Object: We compared the clinical effectiveness and biocompatibility of poly-2-methoxyethyl acrylate (PMEA)-coated and heparin-coated cardiopulmonary bypass (CPB) circuits in a prospective pediatric trial. Methods: Infants randomly received heparin-coated (n=7) or PMEA-coated (n=7) circuits in elective pediatric cardiac surgery with CPB for ventricular septum defects. Clinical and hematologic variables, respiratory indices and hemodynamic changes were analyzed perioperatively. Results: Demographic and clinical variables were similar in both groups. Leukocyte counts were significantly lower 5 minutes after CPB in the PMEA group than the heparin group. Hemodynamic data showed that PMEA caused hypotension within 5 minutes of CPB. The respiratory index was significantly higher immediately after CPB and 1 hour after transfer to the intensive care unit (ICU) in the PMEA group, as were levels of C-reactive protein 24 hours after transfer to the ICU. Conclusion: Our study shows that PMEA-coated circuits, unlike heparin-coated circuits, cause transient leukopenia during pediatric CPB and, perhaps, systemic inflammatory respiratory syndrome after pediatric CPB.
KW - PMEA coating
KW - cardiopulmonary bypass
KW - heparin coating
KW - pediatric
KW - transient leukopenia
UR - http://www.scopus.com/inward/record.url?scp=84960803700&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84960803700&partnerID=8YFLogxK
U2 - 10.1177/0267659115598217
DO - 10.1177/0267659115598217
M3 - Article
C2 - 26228276
AN - SCOPUS:84960803700
SN - 0267-6591
VL - 31
SP - 247
EP - 254
JO - Perfusion (United Kingdom)
JF - Perfusion (United Kingdom)
IS - 3
ER -