TY - JOUR
T1 - Accidental insertion of a percutaneous venovenous cannula into the persistent left superior vena cava of a patient undergoing liver transplantation
AU - Schreiber, Kristin L.
AU - Matsusaki, Takashi
AU - Bane, Brian C.
AU - Bermudez, Christian A.
AU - Hilmi, Ibtesam A.
AU - Sakai, Tetsuro
PY - 2011/7/1
Y1 - 2011/7/1
N2 - Purpose: Persistent left superior vena cava (PLSVC) is a rare congenital vascular abnormality found in 0.3% of the general population. We report herein a rare complication involving the accidental insertion of a large bore cannula into the PLSVC during liver transplantation (LT). Clinical features: A 63-yr-old man with primary sclerosing cholangitis presented for LT. Given the existence of a tunnelled dialysis catheter in the right internal jugular vein (IJV) and a triple lumen catheter via the left IJV, insertion of an 18 French cannula for venovenous bypass (VVB) was performed via the left IJV using the existing triple lumen cannula as a conduit for a guidewire. Upon initiation of VVB, profound systemic hypotension occurred, and liver transplantation was completed without the further use of VVB. A chest x-ray confirmed a malposition of the VVB cannula with a large left hemothorax. A mini-sternotomy was performed for removal of the VVB cannula, which was found to be inserted in the PLSVC. Retrospectively, the presence of PLSVC was not anticipated due to a normal superior vena cava and a left innominate vein, as revealed by the course of a pre-existing left internal jugular vein triple lumen catheter on a preoperative chest x-ray, and due to a normal-sized coronary sinus on preoperative echocardiography. Conclusion: Malpositioning of a venous cannula in a PLSVC should be anticipated as one of the potential complications of vascular access via the left internal jugular vein.
AB - Purpose: Persistent left superior vena cava (PLSVC) is a rare congenital vascular abnormality found in 0.3% of the general population. We report herein a rare complication involving the accidental insertion of a large bore cannula into the PLSVC during liver transplantation (LT). Clinical features: A 63-yr-old man with primary sclerosing cholangitis presented for LT. Given the existence of a tunnelled dialysis catheter in the right internal jugular vein (IJV) and a triple lumen catheter via the left IJV, insertion of an 18 French cannula for venovenous bypass (VVB) was performed via the left IJV using the existing triple lumen cannula as a conduit for a guidewire. Upon initiation of VVB, profound systemic hypotension occurred, and liver transplantation was completed without the further use of VVB. A chest x-ray confirmed a malposition of the VVB cannula with a large left hemothorax. A mini-sternotomy was performed for removal of the VVB cannula, which was found to be inserted in the PLSVC. Retrospectively, the presence of PLSVC was not anticipated due to a normal superior vena cava and a left innominate vein, as revealed by the course of a pre-existing left internal jugular vein triple lumen catheter on a preoperative chest x-ray, and due to a normal-sized coronary sinus on preoperative echocardiography. Conclusion: Malpositioning of a venous cannula in a PLSVC should be anticipated as one of the potential complications of vascular access via the left internal jugular vein.
UR - http://www.scopus.com/inward/record.url?scp=79960456430&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79960456430&partnerID=8YFLogxK
U2 - 10.1007/s12630-011-9510-x
DO - 10.1007/s12630-011-9510-x
M3 - Article
C2 - 21553167
AN - SCOPUS:79960456430
SN - 0832-610X
VL - 58
SP - 646
EP - 649
JO - Canadian Journal of Anaesthesia
JF - Canadian Journal of Anaesthesia
IS - 7
ER -