TY - JOUR
T1 - Bilateral verses bilateral with tri-segmental endoscopic drainage using metal stents for high-grade malignant hilar biliary obstructions
T2 - A multicenter, randomized controlled trial: BRAVE study (BRAVE study)
AU - Matsumoto, Kazuyuki
AU - Mitsuhashi, Toshiharu
AU - Kawamoto, Hirofumi
AU - Ishida, Etsuji
AU - Fujii, Masakuni
AU - Akimoto, Yutaka
AU - Seki, Hiroyuki
AU - Ishihara, Yuki
AU - Ogawa, Taiji
AU - Yamazaki, Tatsuhiro
AU - Fujii, Yuki
AU - Kato, Hironari
N1 - Funding Information:
The study is funded by a Zeon Medical Inc., Tokyo, Japan. The funder has no role or authority over any part of the research process or publication of the trial.
Publisher Copyright:
© 2022 Lippincott Williams and Wilkins. All rights reserved.
PY - 2022/10/7
Y1 - 2022/10/7
N2 - Introduction: Bilateral endoscopic drainage with self-expanding metallic stent (SEMS) can be used to manage hilar malignant biliary obstruction (HMBO) more effectively in comparison to unilateral drainage. An increased drainage area is predicted to prolong stent patency and patient survival. However, few reports have described the utility of trisegmental drainage and the benefits of using trisegmental drainage remain unknown. Thus, we launched a randomized clinical trial (RCT) to compare the clinical outcomes between bilateral and trisegmental drainage using SEMSs in patients with high-grade HMBO. Methods and analysis: This study was conducted as a multicenter randomized control trial (RCT) in 8 high-volume medical centers in Japan, and will prove the non-inferiority of bilateral drainage to trisegmental drainage. Patients with unresectable HMBO with Bismuth type IIIa or IV who pass the inclusion and exclusion criteria will be randomized to receive bilateral or trisegmental drainage at a 1:1 ratio. At each center, the on-site study investigators will obtain informed consent from the candidates, and will use an electronic data capture system (REDCap) to input necessary information, and register candidates with the registration secretariat. The primary endpoint is the rate of non-recurrent biliary obstruction (RBO) at 180 days after SEMSs placement. A-10% non-inferiority margin is assumed in the statistical analysis of the primary endpoint. Secondary endpoints include the rate of technical and clinical success, time to recurrent biliary obstruction (TRBO), causes of RBO, procedure-related adverse events (AEs), procedure time, TRBO with or without endoscopic sphincterotomy, overall survival, and the technical and clinical success rates at reintervention. Discussion: If the non-inferiority of bilateral drainage is demonstrated, it is predicted that the procedure time will be shortened and the medical cost will be reduced, which will be beneficial to the patient and the medical economy. Trial registration: Registered in Japan Registry of Clinical Trial-Registration (trial number. jRCTs062220038). This version number 1. Protocol dated Jun 23, 2022.
AB - Introduction: Bilateral endoscopic drainage with self-expanding metallic stent (SEMS) can be used to manage hilar malignant biliary obstruction (HMBO) more effectively in comparison to unilateral drainage. An increased drainage area is predicted to prolong stent patency and patient survival. However, few reports have described the utility of trisegmental drainage and the benefits of using trisegmental drainage remain unknown. Thus, we launched a randomized clinical trial (RCT) to compare the clinical outcomes between bilateral and trisegmental drainage using SEMSs in patients with high-grade HMBO. Methods and analysis: This study was conducted as a multicenter randomized control trial (RCT) in 8 high-volume medical centers in Japan, and will prove the non-inferiority of bilateral drainage to trisegmental drainage. Patients with unresectable HMBO with Bismuth type IIIa or IV who pass the inclusion and exclusion criteria will be randomized to receive bilateral or trisegmental drainage at a 1:1 ratio. At each center, the on-site study investigators will obtain informed consent from the candidates, and will use an electronic data capture system (REDCap) to input necessary information, and register candidates with the registration secretariat. The primary endpoint is the rate of non-recurrent biliary obstruction (RBO) at 180 days after SEMSs placement. A-10% non-inferiority margin is assumed in the statistical analysis of the primary endpoint. Secondary endpoints include the rate of technical and clinical success, time to recurrent biliary obstruction (TRBO), causes of RBO, procedure-related adverse events (AEs), procedure time, TRBO with or without endoscopic sphincterotomy, overall survival, and the technical and clinical success rates at reintervention. Discussion: If the non-inferiority of bilateral drainage is demonstrated, it is predicted that the procedure time will be shortened and the medical cost will be reduced, which will be beneficial to the patient and the medical economy. Trial registration: Registered in Japan Registry of Clinical Trial-Registration (trial number. jRCTs062220038). This version number 1. Protocol dated Jun 23, 2022.
KW - bilateral drainage
KW - bile duct obstruction
KW - endoscopic biliary drainage
KW - neoplasms
KW - self-expandable metallic stents
UR - http://www.scopus.com/inward/record.url?scp=85139646875&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85139646875&partnerID=8YFLogxK
U2 - 10.1097/MD.0000000000030857
DO - 10.1097/MD.0000000000030857
M3 - Article
C2 - 36221399
AN - SCOPUS:85139646875
SN - 0025-7974
VL - 101
SP - E30857
JO - Medicine; analytical reviews of general medicine, neurology, psychiatry, dermatology, and pediatries
JF - Medicine; analytical reviews of general medicine, neurology, psychiatry, dermatology, and pediatries
IS - 40
ER -