TY - JOUR
T1 - Cholera rapid diagnostic tests for the detection of vibrio cholerae o1
T2 - An updated meta-analysis
AU - Muzembo, Basilua Andre
AU - Kitahara, Kei
AU - Ohno, Ayumu
AU - Debnath, Anusuya
AU - Okamoto, Keinosuke
AU - Miyoshi, Shin Ichi
N1 - Funding Information:
Funding: This study was supported by the Japan Initiative for Global Research Network on Infectious Diseases (J-GRID) from the Ministry of Education, Culture, Sports, Science & Technology in Japan (MEXT), and the Japan Agency for Medical Research and Development (AMED; Grant No. JP20wm0125004). The funders had no role in its study design, data collection and analysis, decision to publish, or preparation of the manuscript.
Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/11
Y1 - 2021/11
N2 - The rapid diagnosis of cholera contributes to adequate outbreak management. This meta-analysis assesses the diagnostic accuracy of cholera rapid tests (RDTs) to detect Vibrio cholerae O1. Methods: Systematic review and meta-analysis. We searched four databases (Medline, EMBASE, Google Scholar, and Web of Science up to 8 September 2021) for studies that evaluated cholera RDTs for the detection of V. cholerae O1 compared with either stool culture or polymerase chain reaction (PCR). We assessed the studies’ quality using the QUADAS-2 criteria. In addition, in this update, GRADE approach was used to rate the overall certainty of the evidence. We performed a bivariate random-effects meta-analysis to calculate the pooled sensitivity and specificity of cholera RDTs. Results: Overall, 20 studies were included in this meta-analysis. Studies were from Africa (n = 11), Asia (n = 7), and America (Haiti; n = 2). They evaluated eight RDTs (Crystal VC-O1, Crystal VC, Cholkit, Institut Pasteur cholera dipstick, SD Bioline, Artron, Cholera Smart O1, and Smart II Cholera O1). Using direct specimen testing, sensitivity and specificity of RDTs were 90% (95% CI, 86 to 93) and 86% (95% CI, 81 to 90), respectively. Cholera Sensitivity was higher in studies conducted in Africa [92% (95% CI, 89 to 94)] compared with Asia [82% (95% CI, 77 to 87)]. However, specificity [83% (95% CI, 71 to 91)] was lower in Africa compared with Asia [90% (95% CI, 84 to 94)]. GRADE quality of evidence was estimated as moderate. Conclusions: Against culture or PCR, current cholera RDTs have moderate sensitivity and specificity for detecting Vibrio cholerae O1.
AB - The rapid diagnosis of cholera contributes to adequate outbreak management. This meta-analysis assesses the diagnostic accuracy of cholera rapid tests (RDTs) to detect Vibrio cholerae O1. Methods: Systematic review and meta-analysis. We searched four databases (Medline, EMBASE, Google Scholar, and Web of Science up to 8 September 2021) for studies that evaluated cholera RDTs for the detection of V. cholerae O1 compared with either stool culture or polymerase chain reaction (PCR). We assessed the studies’ quality using the QUADAS-2 criteria. In addition, in this update, GRADE approach was used to rate the overall certainty of the evidence. We performed a bivariate random-effects meta-analysis to calculate the pooled sensitivity and specificity of cholera RDTs. Results: Overall, 20 studies were included in this meta-analysis. Studies were from Africa (n = 11), Asia (n = 7), and America (Haiti; n = 2). They evaluated eight RDTs (Crystal VC-O1, Crystal VC, Cholkit, Institut Pasteur cholera dipstick, SD Bioline, Artron, Cholera Smart O1, and Smart II Cholera O1). Using direct specimen testing, sensitivity and specificity of RDTs were 90% (95% CI, 86 to 93) and 86% (95% CI, 81 to 90), respectively. Cholera Sensitivity was higher in studies conducted in Africa [92% (95% CI, 89 to 94)] compared with Asia [82% (95% CI, 77 to 87)]. However, specificity [83% (95% CI, 71 to 91)] was lower in Africa compared with Asia [90% (95% CI, 84 to 94)]. GRADE quality of evidence was estimated as moderate. Conclusions: Against culture or PCR, current cholera RDTs have moderate sensitivity and specificity for detecting Vibrio cholerae O1.
KW - Accuracy
KW - Cholera
KW - Rapid test
KW - Sensitivity
KW - Specificity
KW - Update
KW - Vibrio cholera O1
UR - http://www.scopus.com/inward/record.url?scp=85119580403&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119580403&partnerID=8YFLogxK
U2 - 10.3390/diagnostics11112095
DO - 10.3390/diagnostics11112095
M3 - Review article
AN - SCOPUS:85119580403
SN - 2075-4418
VL - 11
JO - Diagnostics
JF - Diagnostics
IS - 11
M1 - 2095
ER -