TY - JOUR
T1 - Determination of lithium contents in silicates by isotope dilution ICP-AAS and its evaluation by isotope dilution thermal ionisation mass spectrometry
AU - Moriguti, Takuya
AU - Makishima, Akio
AU - Nakamura, Eizo
PY - 2004
Y1 - 2004
N2 - A precise and simple method for the determination of lithium concentrations in small amounts of silicate sample was developed by applying isotope dilution-inductively coupled plasma-mass spectrometry (ID-ICP-MS). Samples plus a Li spike were digested with HF-HClO4, dried and diluted with HNO3, and measured by ICP-MS. No matrix effects were observed for 7Li/6Li in rock solutions with a dilution factor (DF) of ≥ 97 at an ICP power of 1.7 kW. By this method, the determination of 0.5 μg g-1 Li in a silicate sample of 1 mg can be made with a blank correction of < 1%. Lithium contents of ultrabasic to acidic silicate reference materials (JP-1, JB-2, JB-3, JA-1, JA-2, JA-3, JR-1 and JR-2 from the Geological Survey of Japan, and PCC-1 from the US Geological Survey) and chondrites (three different Allende and one Murchison sample) of 8 to 81 mg were determined. The relative standard deviation (RSD) was typically < 1.7%. Lithium contents of these samples were further determined by isotope dilution-thermal ionisation mass spectrometry (ID-TIMS). The relative differences between ID-ICP-MS and ID-TIMS were typically < 2%, indicating the high accuracy of ID-ICP-MS developed in this study.
AB - A precise and simple method for the determination of lithium concentrations in small amounts of silicate sample was developed by applying isotope dilution-inductively coupled plasma-mass spectrometry (ID-ICP-MS). Samples plus a Li spike were digested with HF-HClO4, dried and diluted with HNO3, and measured by ICP-MS. No matrix effects were observed for 7Li/6Li in rock solutions with a dilution factor (DF) of ≥ 97 at an ICP power of 1.7 kW. By this method, the determination of 0.5 μg g-1 Li in a silicate sample of 1 mg can be made with a blank correction of < 1%. Lithium contents of ultrabasic to acidic silicate reference materials (JP-1, JB-2, JB-3, JA-1, JA-2, JA-3, JR-1 and JR-2 from the Geological Survey of Japan, and PCC-1 from the US Geological Survey) and chondrites (three different Allende and one Murchison sample) of 8 to 81 mg were determined. The relative standard deviation (RSD) was typically < 1.7%. Lithium contents of these samples were further determined by isotope dilution-thermal ionisation mass spectrometry (ID-TIMS). The relative differences between ID-ICP-MS and ID-TIMS were typically < 2%, indicating the high accuracy of ID-ICP-MS developed in this study.
KW - Isotope dilution-ICP-MS
KW - Lithium
KW - Meteorites
KW - Silicate reference materials
KW - TIMS
UR - http://www.scopus.com/inward/record.url?scp=33646639194&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33646639194&partnerID=8YFLogxK
U2 - 10.1111/j.1751-908X.2004.tb00756.x
DO - 10.1111/j.1751-908X.2004.tb00756.x
M3 - Article
AN - SCOPUS:33646639194
SN - 0150-5505
VL - 28
SP - 371
EP - 382
JO - Geostandards and Geoanalytical Research
JF - Geostandards and Geoanalytical Research
IS - 3
ER -