TY - JOUR
T1 - Extending neutron autoradiography technique for boron concentration measurements in hard tissues
AU - Provenzano, Lucas
AU - Olivera, María Silvina
AU - Saint Martin, Gisela
AU - Rodríguez, Luis Miguel
AU - Fregenal, Daniel
AU - Thorp, Silvia I.
AU - Pozzi, Emiliano C.C.
AU - Curotto, Paula
AU - Postuma, Ian
AU - Altieri, Saverio
AU - González, Sara J.
AU - Bortolussi, Silva
AU - Portu, Agustina
N1 - Funding Information:
This work was partially funded by the Agencia Nacional De Promoción Científica y Tecnológica of Argentina through a PICT Grant no. 2013-1777 , and by the Consejo Nacional De Promoción Científica y Técnica (CONICET) through a PIP Grant no. 112 201301 00458 CO .
Publisher Copyright:
© 2018 Elsevier Ltd
PY - 2018/7
Y1 - 2018/7
N2 - The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 1012 cm−2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis.
AB - The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 1012 cm−2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis.
KW - BNCT
KW - Bone
KW - Neutron autoradiography
UR - http://www.scopus.com/inward/record.url?scp=85044452979&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85044452979&partnerID=8YFLogxK
U2 - 10.1016/j.apradiso.2018.03.011
DO - 10.1016/j.apradiso.2018.03.011
M3 - Article
C2 - 29587160
AN - SCOPUS:85044452979
SN - 0969-8043
VL - 137
SP - 62
EP - 67
JO - Applied Radiation and Isotopes
JF - Applied Radiation and Isotopes
ER -