TY - JOUR
T1 - Single-session esophagogastroduodenoscopy and endoscopic ultrasound using a forward-viewing radial scan ultrasonic endoscope
AU - Uchida, Daisuke
AU - Kato, Hironari
AU - Matsumoto, Kazuyuki
AU - Ishihara, Yuki
AU - Matsumi, Akihiro
AU - Saragai, Yosuke
AU - Takada, Saimon
AU - Yabe, Shuntaro
AU - Muro, Shinichiro
AU - Tomoda, Takeshi
AU - Horiguchi, Shigeru
AU - Okada, Hiroyuki
N1 - Publisher Copyright:
© 2019 The Author(s).
PY - 2019/12/18
Y1 - 2019/12/18
N2 - Background: Endoscopic ultrasound is useful for obtaining high-resolution images of pancreaticobiliary diseases, but is not readily available for physical checkups. In this study, we evaluated the safety and efficacy of single-session esophagogastroduodenoscopy and endoscopic ultrasound in the detection of upper-gastrointestinal and pancreaticobiliary diseases using a forward-viewing radial scan ultrasonic endoscope. Methods: A total of 148 patients who were scheduled for upper-gastrointestinal screening using an endoscope were prospectively included. All patients were examined by EUS in combination with EGD using a forward-viewing radial scan ultrasonic endoscope. The primary endpoint was the safety of the procedures. The secondary endpoints were the prevalence of diseases, the basal imaging capability of EUS, the procedure time, total dose of propofol, and the correlation between background factors and the prevalence of pancreatic disease. The imaging capability at each region was scored as 0 (invisible) to 2 (sufficient visualization to evaluate the organs). Results: Intraoperative hypotension occurred as an adverse event of intravenous anesthesia in one patient. There were 82 pancreaticobiliary findings and 165 upper-gastrointestinal findings (malignancy not included). Follicular lymphoma of the intra-abdominal lymph nodes was detected in one patient. The mean imaging scores of each section were 1.95 (pancreatic head and papilla), 2.0 (pancreatic body), 1.99 (pancreatic tail), and 1.89 (common bile duct and gallbladder). Age, history of diabetes mellitus, and smoking history were significantly associated with the prevalence of pancreatic diseases. Conclusion: The simultaneous performance of EGD and EUS using a new ultrasonic endoscope is tolerable and safe for upper-gastrointestinal and pancreaticobiliary screening.
AB - Background: Endoscopic ultrasound is useful for obtaining high-resolution images of pancreaticobiliary diseases, but is not readily available for physical checkups. In this study, we evaluated the safety and efficacy of single-session esophagogastroduodenoscopy and endoscopic ultrasound in the detection of upper-gastrointestinal and pancreaticobiliary diseases using a forward-viewing radial scan ultrasonic endoscope. Methods: A total of 148 patients who were scheduled for upper-gastrointestinal screening using an endoscope were prospectively included. All patients were examined by EUS in combination with EGD using a forward-viewing radial scan ultrasonic endoscope. The primary endpoint was the safety of the procedures. The secondary endpoints were the prevalence of diseases, the basal imaging capability of EUS, the procedure time, total dose of propofol, and the correlation between background factors and the prevalence of pancreatic disease. The imaging capability at each region was scored as 0 (invisible) to 2 (sufficient visualization to evaluate the organs). Results: Intraoperative hypotension occurred as an adverse event of intravenous anesthesia in one patient. There were 82 pancreaticobiliary findings and 165 upper-gastrointestinal findings (malignancy not included). Follicular lymphoma of the intra-abdominal lymph nodes was detected in one patient. The mean imaging scores of each section were 1.95 (pancreatic head and papilla), 2.0 (pancreatic body), 1.99 (pancreatic tail), and 1.89 (common bile duct and gallbladder). Age, history of diabetes mellitus, and smoking history were significantly associated with the prevalence of pancreatic diseases. Conclusion: The simultaneous performance of EGD and EUS using a new ultrasonic endoscope is tolerable and safe for upper-gastrointestinal and pancreaticobiliary screening.
KW - Biliary tract diseases
KW - Diagnostic screening program
KW - Endoscopic ultrasound
KW - Pancreatic diseases
UR - http://www.scopus.com/inward/record.url?scp=85076919851&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85076919851&partnerID=8YFLogxK
U2 - 10.1186/s12876-019-1141-7
DO - 10.1186/s12876-019-1141-7
M3 - Article
C2 - 31852458
AN - SCOPUS:85076919851
SN - 1471-230X
VL - 19
JO - BMC Gastroenterology
JF - BMC Gastroenterology
IS - 1
M1 - 220
ER -