Suppression of mode conversion by installing bypass capacitor to power distribution network

研究成果査読

1 被引用数 (Scopus)

抄録

In the modal-equivalent circuit derived from the view of the mode-decomposition technique, mode-conversion sources are placed at the interface where the imbalance factor of the transmission lines changes. In addition, the amount of the mode-conversion sources is proportional to not only the difference in the imbalance factor but also the magnitudes of the normal-mode voltage and the common-mode current at the same position. In this paper, therefore, the suppression of mode conversion from normal mode to common mode is experimentally examined by installing a bypass capacitor to power distribution network. The bypass capacitor helps reduce the normal-mode voltage in the vicinity of a connector on a test board where mode conversion occurs so that the common-mode current flowing a power-line cable and the electric field far from the test board are decreased. In fact, the mode conversion was most suppressed when the bypass capacitor is placed closest to the connector on the test board. Also, it was found that the mode conversion was suppressed by the capacitor installed to the power-line cable in the vicinity of the connector.

本文言語English
ページ(範囲)25-32
ページ数8
ジャーナルIEEJ Transactions on Fundamentals and Materials
136
1
DOI
出版ステータスPublished - 1月 1 2016

ASJC Scopus subject areas

  • 電子工学および電気工学

フィンガープリント

「Suppression of mode conversion by installing bypass capacitor to power distribution network」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル