抄録
Objective: The purpose of this study was to investigate if incremental-filling technique and cavity size would affect the bond strength of resin composite. Methods: Two sizes of Class I cavities were prepared in bovine dentin (large cavities: π × (5/2)2 × 5 mm3; small cavity: π × (3/2)2 × 3 mm3). Light-cure resin composite (Clearfil Photocore) with a self-etching primer adhesive (Clearfil SE Bond) was placed into the cavities by bulk filling (C-factor = 5) or incremental filling (two layers, C-factor = 3) and light-cured. As a control, 3 or 5 mm thick resin composite was bonded to the flat dentin surface. After 24 h storage in 37 °C water, the micro-tensile bond strength was measured at a crosshead speed of 1 mm/min. The results obtained were statistically analyzed using two-way ANOVA and t-test at a significance level of P = 0.05. Results: The results obtained showed that there was no significant difference among the filling techniques in small cavities (P > 0.05). However, in large cavities, bulk filling presented the lowest bond strength (P < 0.05). Significance: Not only the filling technique affected the bonding strength to the cavity floor, but the cavity size was also an influential factor in Class I cavities.
| 本文言語 | English |
|---|---|
| ページ(範囲) | 533-538 |
| ページ数 | 6 |
| ジャーナル | Dental Materials |
| 巻 | 23 |
| 号 | 5 |
| DOI | |
| 出版ステータス | Published - 4月 2007 |
| 外部発表 | はい |
ASJC Scopus subject areas
- 材料科学一般
- 歯学一般
- 材料力学
フィンガープリント
「The effects of cavity size and incremental technique on micro-tensile bond strength of resin composite in Class I cavities」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。引用スタイル
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX